...
首页> 外文期刊>Indian Journal of Dental Research >The effect of implant design on the stress distribution in a three-unit implant-supported distal cantilever fixed partial denture: A three-dimensional finite-element analysis
【24h】

The effect of implant design on the stress distribution in a three-unit implant-supported distal cantilever fixed partial denture: A three-dimensional finite-element analysis

机译:种植体设计对三单元种植体支撑的远端悬臂固定局部义齿中应力分布的影响:三维有限元分析

获取原文
           

摘要

Context: Implant design influences the stress distribution in an implant-supported distal cantilever fixed partial denture and supporting bone tissue. Aim: The purpose of this study was to investigate the effect of implant design on the stress distribution in the framework, implant, and surrounding bone, using a three-dimensional finite-element analysis. Materials and Methods: A three-dimensional finite-element model of a mandibular section of bone with implants placed in the first and second premolar region was created to support a distal cantilever fixed partial denture. A one-piece and two-piece implant and its suprastructure were simulated into wire frame models using Pro engineer (Pro E) program. Four models were created in this study. Results: Comparative analysis of all models showed that the maximum stress overall was in the cervical portion of the secondary abutment. When used in combination, the maximum stress was when the two-piece implant was used as secondary abutment. The one-piece implant showed less stress compared to its counterpart when used as secondary abutment. The maximum stress distribution in the bone was around the neck region of the secondary implant. Conclusion: Within the limitations of this study, it can be concluded that stress distribution is better in a one-piece implant design when compared with the two-piece implant design, with stress concentration being more at the junction of the abutment and the implant fixture in the two-piece implant. When implants are used as abutments (either primary or secondary), irrespective of their position and design, the secondary implant shows the maximum amount of stresses.
机译:背景:种植体设计会影响种植体支撑的远端悬臂固定局部义齿和支撑骨组织中的应力分布。目的:本研究的目的是使用三维有限元分析来研究植入物设计对框架,植入物和周围骨骼中应力分布的影响。材料和方法:创建了一个种植体放置在第一和第二前磨牙区域中的下颌骨的三维有限元模型,以支持远端悬臂固定局部义齿。使用Pro Engineer(Pro E)程序将一件和两件式植入物及其上部结构仿真到线框模型中。在这项研究中创建了四个模型。结果:所有模型的比较分析显示,最大应力总体位于次要基牙的颈部。当组合使用时,最大应力是当两件式植入物用作辅助基台时。当用作第二基台时,一件式种植体与其对应的种植体相比应力较小。骨骼中的最大应力分布在辅助植入物的颈部周围。结论:在这项研究的局限性内,可以得出结论,与两件式种植体设计相比,一件式种植体设计的应力分布更好,并且在基台和种植体固定装置的交界处应力集中更大在两件式植入物中。当使用植入物作为基台(主要或次要)时,无论其位置和设计如何,次要植入物均显示出最大的应力量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号