The reliability of cephalometric measurements in oral and maxillofacial imaging: Cone beam computed tomography versus two-dimensional digital cephalograms

机译:口腔颌面影像学中头颅测量的可靠性:锥形束计算机断层扫描与二维数字化头颅图

获取原文
           

摘要

Context: This study compared digital two-dimensional (2D) lateral cephalograms and cone-beam computed tomography (CBCT) total and half-skull images for thereliability of cephalometric measurements. Aims: (1) To compare the accuracy of cephalometric measurements and reproducibility between the digital and CBCTcephalograms in the Indian population. (2) To compare interobserver variability in landmark identification through their cephalometric measurements by comparingdifferent imaging modalities (CBCT total skull, CBCT half-skull, and conventional lateral cephalogram). (3) To further compare half-skull with the total skullsynthesized CBCT and digital cephalograms in the same regard. Materials and Methods: Thirty patients, who had consented with orthodontic treatment,participated in the study. Informed consent was obtained from the patient before the radiographic procedures. 2D digital lateral cephalograms and their correspondingCBCT scans were taken and imported in DICOM format to OnDemand 3D software. Twenty-three landmarks were identified by 3 observers and 9 linear and 14angular measurements were digitally traced. The values were sent for statistical analysis using ANOVA to check the interobserver reliability between the imagingmodalities. Statistical Analysis Used: ANOVA, Student?SQ?s t-test, and post hoc test were used for the statistical analysis. Results: The interobserver reliabilitywas high between the modalities. CBCT total skull received an overall intraclass correlation coefficient (ICC) value of 0.76. The ICC value for the CBCT half-skullwas 0.79 and for the digital cephalograms it was 0.80. The reliability for CBCT total skull was marginally less when compared to the CBCT half-skull and digitalcephalograms, but more for the mid-sagittal measurements. Digital cephalograms showed the most variation with measurements of the mandibular plane whencompared to CBCT. Conclusions: CBCT has the potential to be used for cephalometrics, especially the half-skull images, but further studies are required to provewhether CBCT total skull images can be used. 2D cephalometry, however, still does remain as the mainstay of orthodontic diagnosis and treatment planning andcannot be easily replaced by three-dimensional cephalometry.
机译:背景:本研究比较了数字二维(2D)侧位头颅图和锥形束计算机断层扫描(CBCT)的总和半颅骨图像,以确保头部测量的可靠性。目的:(1)比较印度人群中头颅测量的准确性和数字化和CBCT头颅图之间的可重复性。 (2)通过比较不同的成像方式(CBCT全颅骨,CBCT半颅骨和常规侧位脑波图),通过头颅测量来比较地标识别者之间的差异。 (3)在相同方面进一步比较半颅骨与颅骨合成的CBCT和数字脑电图。材料与方法:30名同意正畸治疗的患者参加了该研究。在进行射线照相术之前已获得患者的知情同意。拍摄2D数字侧位脑波图及其相应的CBCT扫描,并以DICOM格式导入到OnDemand 3D软件中。由3个观察者识别了23个地标,并数字跟踪了9个线性和14个角度的测量值。使用ANOVA将值发送到统计分析,以检查成像模态之间的观察者间可靠性。使用的统计分析:使用ANOVA,Student?SQ?t检验和事后检验进行统计分析。结果:观察者之间的可靠性很高。 CBCT总颅骨的整体类内相关系数(ICC)值为0.76。 CBCT半颅骨的ICC值为0.79,数字头颅造影的ICC值为0.80。与CBCT半颅骨和数字脑电图相比,CBCT全颅骨的可靠性略低,但矢状中位测量的可靠性更高。与CBCT相比,数字脑电图显示下颌平面测量值变化最大。结论:CBCT有可能用于头颅测量,尤其是半颅骨图像,但是需要进一步研究以证明是否可以使用CBCT全颅骨图像。然而,2D头颅测量法仍然仍然是正畸诊断和治疗计划的主要内容,不能轻易地用3D头颅测量法代替。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号