The proposed Autonomous Stress Indicator (ASI) is a device that monitors the contents of the protection relays on a suspect weak power system bus and generates a performance level related to the degree of system performance degradation or instability.  This gives the system operators some time (minutes) to take corrective action.  In a given operating area there would not likely be a need for an ASI on every bus.  Note that the ASI does not trip any breakers; it is an INFORMATION ONLY device.  An important feature is that the system operator can subsequently interrogate the ASI to determine the factor(s) that led to the performance level that has been initially annunciated, thereby leading to a course of action. This paper traces the development of the ASI which is an ongoing project. The ASI could be also described as a stress-alert device whose function is to alert the System Operator of a stressful condition at its location. The characteristics (or essential qualities) of this device are autonomy, selectivity, accuracy and intelligence. These will fulfill the requirements of the recommendation of the Canada –US Task Force in the August 2003 system collapse. Preliminary tests on the IEEE 39-bus model indicate that the concept has merit and development work is in progress. While the ASI can be applied to all power system operating conditions, its principal application is to the degraded state of the system where the System Operator must act to restore the system to the secure state before it migrates to a stage of collapse. The work of ASI actually begins with the Areas of Vulnerability and ends with the Predictive Module as described in detail in this paper. An application example of a degraded system using the IEEE 39-bus system is included.
机译:提出的自主应力指示器(ASI)是一种用于监视可疑的弱电系统总线上的保护继电器的内容并生成与系统性能下降或不稳定程度相关的性能水平的设备。这使系统操作员有一些时间(分钟)采取纠正措施。在给定的操作区域中,可能不会在每条总线上都需要ASI。请注意,ASI不会使任何断路器跳闸。它是仅信息设备。一个重要的特征是系统操作员可以随后查询ASI,以确定导致最初宣布的性能水平的因素,从而采取行动。本文跟踪了正在进行的项目ASI的开发。 ASI也可以描述为压力警报设备,其功能是向系统操作员警告其所在位置的压力状况。该设备的特征(或基本质量)是自治性,选择性,准确性和智能性。这些将满足加拿大-美国工作队在2003年8月系统崩溃中所提建议的要求。对IEEE 39总线模型的初步测试表明,该概念很有用,开发工作正在进行中。虽然ASI可以应用于所有电力系统运行状况,但其主要应用是在系统的降级状态,在此状态下,系统操作员必须采取行动,才能将系统恢复到安全状态,然后再迁移到崩溃状态。 ASI的工作实际上始于漏洞领域,最后以预测模块结束,如本文中详细描述的那样。包括使用IEEE 39总线系统的降级系统的应用示例。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号