首页> 外文期刊>Current Chemistry Letters >Potentiometric determination of piroxicam and oxfendazole in pharmaceuticals
【24h】

Potentiometric determination of piroxicam and oxfendazole in pharmaceuticals

机译:电位测定法测定吡罗昔康和奥芬达唑

获取原文
   

获取外文期刊封面封底 >>

       

摘要

Piroxicam (POC) and oxfendazole (OFA) are two widely used veterinary non-steroidal anti-inflammatory and anthelmintic medicines, respectively. Simple, precise and accurate and cost-effective methods for the determination of POC and OFZ in bulk drug and in its dosage forms have been developed and validated. The methods are based on the potentiometric titration of compound with acetous perchloric acid in glacial acetic acid medium using modified glass-saturated calomel electrode system. The methods are applicable over the ranges 1.5 - 15 mg and 7.5-15 mg, for POC and OFA, respectively. The proposed methods were successfully applied to the determination of active substances in their pharmaceutical dosage forms. A statistical comparison was made on the results of proposed methods with those obtained for reference method. The intra-day and inter-day precision and accuracy values obtained were satisfactory with RSD and RE values less than 3%. Excipients in tablets did not interfere to the assay as shown by the recovery study via standard addition technique with mean percentage recoveries in the range 97.8 – 100.6%
机译:吡罗昔康(POC)和奥芬达唑(OFA)分别是两种广泛使用的兽用非甾体类抗炎药和驱虫药。已经开发并验证了简单,精确,准确和经济高效的方法来测定散装药物及其剂型中的POC和OFZ。该方法基于使用改良的玻璃饱和甘汞电极系统在冰醋酸介质中用高氯酸乙酸滴定化合物的电位。该方法适用于POC和OFA的范围分别为1.5-15 mg和7.5-15 mg。所提出的方法已成功应用于药物剂型中活性物质的测定。对建议方法的结果与参考方法获得的结果进行统计比较。 RSD和RE值小于3%时,获得的日内和日间精度和准确度值令人满意。通过标准添加技术进行的回收率研究表明,片剂中的赋形剂不会干扰测定,平均回收率范围为97.8 – 100.6%

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号