首页> 外文期刊>Computer Assisted Surgery >Accuracy of estimating Unicondylar Knee Replacement implant varus/valgus angles from antero-posterior radiographs
【24h】

Accuracy of estimating Unicondylar Knee Replacement implant varus/valgus angles from antero-posterior radiographs

机译:从前后X线片估计单con膝关节置换植入物内翻/外翻角度的准确性

获取原文
           

摘要

Unicondylar Knee Replacement (UKR) is an orthopedic surgical procedure to reduce pain and improve function in the knee. Load-bearing long-standing antero-posterior (AP) radiographs are typically used postoperatively to measure the leg alignment and assess the varus/valgus implant orientation. However, implant out-of-plane rotations, user variability, and X-ray acquisition parameters introduce errors in the estimation of the implant varus/valgus estimation. Previous work has explored the accuracy of various imaging modalities in this estimation. In this work, we explored the impact of out-of-plane rotations and X-ray acquisition parameters on the estimation of implant component varus/valgus angles. For our study, we used a single CT scan and positioned femoral and tibial implants under varying orientations within the CT volume. Then, a custom software application was used to obtain digitally reconstructed radiographs from the CT scan with implants under varying orientations. Two users were then asked to manually estimate the varus/valgus angles for the implants. We found that there was significant inter-user variability (p ??0.05) in the varus/valgus estimates for the two users. However, the ‘ideal’ measurements, obtained using actual implant orientations, showed small errors due to variations in implant orientation. We also found that variation in the projection center does not have a statistically significant impact (p ??0.01) on the estimation of implant varus/valgus angles. We conclude that manual estimates of UKR implant varus/valgus orientations are unreliable.
机译:单con膝关节置换术(UKR)是一种整形外科手术方法,可以减轻疼痛并改善膝盖的功能。术后长期使用承重的长期前后X线照片来测量腿部对齐并评估内翻/外翻植入物的方向。但是,植入物平面外旋转,用户变异性和X射线采集参数会在植入物内翻/外翻估计的估计中引入误差。先前的工作已经探索了这种估计中各种成像模态的准确性。在这项工作中,我们探索了平面外旋转和X射线采集参数对植入物成分内翻/外翻角估计的影响。对于我们的研究,我们使用单次CT扫描,并在CT体积内以不同方向放置股骨和胫骨植入物。然后,使用定制软件应用程序从具有不同方向的植入物的CT扫描中获取数字重建的X射线照片。然后要求两个用户手动估计植入物的内翻/外翻角度。我们发现,两个用户的内翻/外翻估计值之间存在显着的用户间差异(> <0.05)。但是,由于种植体方向的变化,使用实际种植体方向获得的“理想”测量结果显示出很小的误差。我们还发现,投影中心的变化对植入物内翻/外翻角的估计没有统计学上的显着影响(p <0.01)。我们得出的结论是,人工估算UKR植入物内翻/外翻的方向是不可靠的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号