首页> 外文期刊>Circulation journal >Diagnostic Performance of the Simultaneous Acquisition Rest 99 mTc-Tetrofosmin/Stress 201Tl Dual-Isotope Protocol With a Semiconductor Camera ― Comparison With the Rest-Stress 99 mTc-Tetrofosmin Protocol ―
【24h】

Diagnostic Performance of the Simultaneous Acquisition Rest 99 mTc-Tetrofosmin/Stress 201Tl Dual-Isotope Protocol With a Semiconductor Camera ― Comparison With the Rest-Stress 99 mTc-Tetrofosmin Protocol ―

机译:半导体摄像头同时采集静止99 mTc-Tetrofosmin / Stress 201Tl双同位素协议的诊断性能―与Rest-Stress 99 mTc-Tetrofosmin协议的比较―

获取原文
           

摘要

Background: This study compared the diagnostic value of myocardial perfusion imaging (MPI) between the rest-stress 99 mTc-tetrofosmin protocol (Tc/Tc protocol) and simultaneous acquisition rest 99 mTc-tetrofosmin/stress 201Tl dual-isotope protocol (SDI protocol) with a semiconductor camera. Methods?and?Results: We retrospectively studied 147 patients who underwent stress MPI using a cadmium-zinc-telluride camera and invasive coronary angiography within a 3-month interval. The Tc/Tc and SDI protocols were used in 59 and 88 patients, respectively. The sensitivity, specificity, and accuracy of the summed difference score in per-patient analysis were 56%, 85%, and 69%, respectively, for the Tc/Tc protocol and 89%, 82%, and 85%, respectively, for the SDI protocol. The area under the receiver operating characteristic curve was significantly better for the SDI than Tc/Tc protocol for the left anterior descending artery (0.836 vs. 0.674; P=0.0380), the left circumflex artery (0.754 vs. 0.599; P=0.0441), and in per-patient analysis (0.875 vs. 0.707; P=0.0135). There was no significant difference in the diagnostic accuracy of the summed stress score for any vessel or in per-patient analysis between the 2 protocols. Conclusions: The SDI protocol had a higher diagnostic accuracy for the detection of coronary ischemia than the Tc/Tc protocol.
机译:背景:本研究比较了静息99 mTc-四氟膦敏方案(Tc / Tc方案)和同时采集静息99 mTc-四氟磷精/应力201Tl双同位素方案(SDI方案)之间的心肌灌注成像(MPI)的诊断价值。用半导体相机。方法和结果:我们回顾性研究了147名接受镉-锌-碲化物照相机并在3个月内进行有创冠状动脉造影的压力MPI患者。 Tc / Tc和SDI方案分别用于59例和88例患者。对于Tc / Tc方案,每位患者分析总和差异得分的敏感性,特异性和准确性分别为56%,85%和69%,对于Tc / Tc方案分别为89%,82%和85%。 SDI协议。对于SDI,接收器工作特性曲线下的面积明显好于Tc / Tc方案,左前降支动脉(0.836 vs. 0.674; P = 0.0380),左旋支动脉(0.754 vs. 0.599; P = 0.0441) ,以及每位患者的分析结果(0.875对0.707; P = 0.0135)。在两种方案之间,任何血管的总压力评分的诊断准确性或每位患者的分析都没有显着差异。结论:SDI协议比Tc / Tc协议具有更高的诊断冠状动脉缺血的诊断准确性。

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号