Background Dominant frequency (DF) analysis of atrial electrograms has become an important method in characterizing atrial fibrillation (AF). As a classic method, Botteron’s approach is widely used in the preprocessing of frequency analysis during AF. It includes three steps: (1) band-pass filtering at 40–250?Hz, (2) absolute value, and (3) low-pass filtering at 20?Hz. This paper aims to expound the necessity and adjustability of each step. Methods and results Unipolar epicardial mapping signals were recorded during AF from eight mongrel dogs with cholinergic AF model. Episodes of these data were randomly selected to evaluate the impact of different pass bands and the necessity of low-pass filtering with 20?Hz cutoff frequency. Each episode of AF signal is 5?s long with a sampling rate of 2?kHz. Simulated electrograms were adopted to discuss the role of taking absolute value. Furthermore, direct spectral analysis method (FFT et al.) is compared with Botteron’s preprocessing approach. According to our statistical analysis, the pass band of 40–250?Hz was not the best, while 20–100?Hz presented the high accuracy rate of DF. From the comparing result of direct FFT without Botteron’s approach we deduced that the rectification of absolute value was meaningful for the fundamental atrial frequency. The final step, 20?Hz low-pass filter can completely be omitted in DF analysis. In consideration of the demand for real-time distribution of DF in clinical or experimental situations, down-sampling method and the impact of ventricular artifacts on DF was also discussed. Conclusion In the actual application of the three preprocessing steps, the pass band selection of band-pass filter can be adjusted and the rectification of taking absolute value is important. Nevertheless, the final step of 20?Hz low-pass filter is totally unnecessary. In real-time signal processing situations, taking down-sampling method and ignoring the ventricular artifacts can also have high performance in DF analysis of atrial electrograms.
展开▼