To present the follow-up outcomes of a modified technique of transscleral suture fixation of posterior chamber intraocular lens (PCIOL) in eyes with inadequate capsule support. A retrospective chart review of 21 patients underwent transscleral suture fixation of a foldable 3-looped haptics one-piece PCIOL implantation through scleral pockets was conducted. Preoperative data and follow-up data for at least 3?months were collected for all patients. The mean operative duration was 36.62?±?10.70?min. The mean pre- and post-operative LogMAR uncorrected distance visual acuity was (1.25?±?0.50 vs. 0.41?±?0.22, P??0.01). The mean pre- and post-operative LogMAR best corrected visual acuity was (0.48?±?0.25 vs. 0.33?±?0.24, P??0.01). The mean proportion of postoperative endothelial cell loss was 11.46?±?4.78%. The mean postoperative anterior chamber depth was 3.05?±?0.44?mm. The mean postoperative IOL tilt degree was 2.81?±?1.41°, and the mean postoperative IOL decentration degree was 0.31?±?0.13?mm. Four patients with transient corneal edema (19.0%) and three patients with transiently elevated IOP (14.3%) were observed after operation, and such complications were resolved within 1?week. No severe complications were observed. The modified technique was a feasible method of PCIOL implantation.
机译:本文介绍了在囊膜支持不足的情况下经后巩膜人工晶状体(PCIOL)经巩膜缝线固定的改良技术的随访结果。回顾性图表回顾了21例患者通过巩膜袋经可折叠的3环触觉单件PCIOL植入巩膜缝合术。收集所有患者至少3个月的术前数据和随访数据。平均手术时间为36.62±10.70min。术前和术后LogMAR未经校正的远距离视力的平均值为(1.25±±0.50 vs. 0.41±±0.22,P 0.01)。术前和术后LogMAR最佳矫正视力的平均值为(0.48?±?0.25 vs. 0.33?±?0.24,P?<?0.01)。术后内皮细胞损失的平均比例为11.46±±4.78%。术后平均前房深度为3.05?±?0.44?mm。术后平均IOL倾斜度为2.81±1.01mm,平均IOL偏心度为0.31±0.13mm。术后观察到4例短暂性角膜水肿(19.0%)和3例短暂性眼压升高(14.3%),并在1周内解决了这些并发症。没有观察到严重的并发症。改进的技术是PCIOL植入的可行方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号