首页> 外文期刊>Dental materials >Bond angle effects on microtensile bonds: Laboratory and FEA comparison
【24h】

Bond angle effects on microtensile bonds: Laboratory and FEA comparison

机译:键角对微拉伸键的影响:实验室和有限元分析的比较

获取原文
获取原文并翻译 | 示例
           

摘要

Objective. To test the hypothesis that there is a reduction in bond strength when a microtensile load is applied to adhesive junctions prepared at 10, 20 and 30 degrees to the usual perpendicular interface. To evaluate the effect of bond angle and adhesive layer thickness on stress levels within the adhesive joint utilizing FEA. Methods. Twenty-four non-carious third molars were selected, occlusal enamel removed and polished perpendicular to the long axis of the tooth. The Clearfil SE Bond and Single Bond were applied on the dentin. A 4 mm resin restoration, Z 100, was built up. The teeth were sectioned at 10°, 20° and 30° to the bonding interface (n = 3). The control (n = 3) group had all cuts parallel to the tooth longitudinal axis (0? bond angle). The bond values were calculated in MPa and Two-Way ANOVA and Tukey test applied. FEA was performed (1 mm/side square specimens) to obtain the maximum principal stress (MPS) in the microtensile-model for each bond angle and for varying adhesive thickness from 20 μm to 200 μm for each group. Results. The bond strength results diminish as the angle on the interface increased (P < 0.05) for Clearfil SE Bond between 0 (control) and 30 degrees, and for Single Bond between 0 (control) and 10, 20, and 30 degrees. The hypothesis can be fully accepted for Single Bond and partially accepted for Clearfil SE Bond. For the FEA, there was a trend toward decreasing MPS as the bond angle increased, while the MPS for each angled group increased with adhesive layer thickness. Significance. The MPS results for angled interfaces, exhibited the same trend as the lab values. FEA results indicated an MPS increase with increased adhesive thickness.
机译:目的。为了检验以下假设:当向与垂直界面交界的10、20和30度制备的胶粘剂连接处施加微拉伸载荷时,粘结强度会降低。为了评估粘结角度和粘结层厚度对利用FEA的粘结接头内应力水平的影响。方法。选择二十四个非龋齿的第三磨牙,去除牙合釉并垂直于牙齿的长轴抛光。将Clearfil SE键和单键施加在牙本质上。搭建了一个4毫米的树脂修复体Z 100。牙齿以10°,20°和30°的角度与粘合界面(n = 3)切开。对照组(n = 3)的所有切口均平行于牙齿纵轴(0°θ粘结角)。键值以MPa计算,并应用双向方差分析和Tukey测试。进行FEA(1毫米/边方样品)以获得微拉伸模型中每个粘结角的最大主应力(MPS),并使每个组的粘合剂厚度从20μm变至200μm。结果。当Clearfil SE Bond在0(对照)和30度之间以及对于Single Bond(在0(对照)和10、20和30度之间)时,粘合强度结果随界面角度的增加而减小(P <0.05)。该假设可以被Single Bond完全接受,对于Clearfil SE Bond可以部分接受。对于FEA,随着粘结角的增加,MPS呈下降趋势,而每个成角度组的MPS随粘合剂层厚度的增加而增加。意义。倾斜接口的MPS结果显示出与实验室值相同的趋势。 FEA结果表明MPS随着胶粘剂厚度的增加而增加。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号