首页> 外文期刊>Construction and Building Materials >Minimum shear reinforcement for ultra-high performance fiber reinforced concrete deep beams
【24h】

Minimum shear reinforcement for ultra-high performance fiber reinforced concrete deep beams

机译:超高性能纤维增强混凝土深梁的最小抗剪钢筋

获取原文
获取原文并翻译 | 示例
           

摘要

This research aimed to study the minimum requirements of shear reinforcement for ultra high performance fiber reinforced concrete deep beams. The experimental results showed that increasing the provided vertical web reinforcement ratio has slight effect on the diagonal cracking strength and the ultimate shear strength. The maximum spacing between the vertical web reinforcement required by ACI 318-2014 for reinforced concrete beams (d/5) is not suitable for ultra-high performance fiber reinforced concrete deep beams, while for the EC-2 (2b) and that required by the Egyptian code ECP-203-2017 (200 mm) is applicable. The recommendations of AFGC-2013 and KCI-2012 are safe and conservative more than that required by ACI 318-2014. (C) 2018 Published by Elsevier Ltd.
机译:这项研究旨在研究超高性能纤维增强混凝土深梁的抗剪钢筋的最低要求。实验结果表明,增加所提供的竖向腹板增强比对斜向抗裂强度和极限抗剪强度影响不大。 ACI 318-2014对钢筋混凝土梁(d / 5)要求的垂直腹板钢筋之间的最大间距不适用于超高性能纤维增强混凝土深梁,而对于EC-2(2b)和适用埃及法规ECP-203-2017(200毫米)。 AFGC-2013和KCI-2012的建议比ACI 318-2014所要求的更为安全和保守。 (C)2018由Elsevier Ltd.发布