Early warning detection of runaway initiation using non-linear approaches

机译:使用非线性方法预警失控引发

获取原文
获取原文并翻译 | 示例
           

摘要

We present a method for early detection of runaway initiation in chemical reactors using only temperature measurements and based on the calculation of the divergence of the system. The method is based on state space reconstruction techniques and is illustrated using simulated as well as experimental datasets. The results show that the method is able to distinguish between runaway and non-runaway situations and it does not produce false alarms during controlled heating/cooling experiments.
机译:我们提出了一种仅使用温度测量值并基于系统发散度的计算方法就可以早期检测化学反应堆中失控引发的方法。该方法基于状态空间重构技术,并使用模拟数据集和实验数据集进行了说明。结果表明,该方法能够区分失控和非失控情况,并且在受控的加热/冷却实验过程中不会产生误报。