The aim of this paper is to introduce a methodology which enables to revise the limit values of the heat transfer coefficient in accordance with the building form with respect to thermal comfort and energy conservation. In this study, the building form is represented by the ratio of the total facade area to building volume (A/V). As the building form and the heat transfer coefficient (U value) of a building are the most important parameters affecting indoor climate, they have been taken into consideration in detail. The proposed methodology enables to determine the limit values of the building envelope heat transfer coefficients on the basis of A/V ratios and other design parameters affecting indoor thermal comfort and energy conservation such as orientation, window type, optical and thermophysical properties of the building envelope. The methodology has been applied for temperate and cold zones of Turkey and the results of the application are given by sample graphics in the paper.
机译:本文的目的是介绍一种方法,该方法能够根据建筑形式在热舒适性和节能方面修改传热系数的极限值。在本研究中,建筑形式由总立面面积与建筑体积的比率(A / V)表示。由于建筑物的形式和建筑物的传热系数(U值)是影响室内气候的最重要参数,因此已对其进行了详细考虑。所提出的方法能够基于A / V比和影响室内热舒适性和节能的其他设计参数(例如建筑物的方向,窗户类型,光学和热物理性质)来确定建筑物围护结构传热系数的限值。 。该方法已应用于土耳其的温带和寒冷地区,其应用结果通过本文中的示例图形给出。