Numerical simulation and experimental measurement of flow and concentration fields in a working fan-filter-unit (FFU) cleanroom have been conducted in this study. The purpose of the study is to find out the unsteady concentration distribution of a leaking gas pollutant. The standard K-ε model was used for the simulation of the flow field. To obtain the gas concentration field, SF_6 gas with a certain concentration was released as a simulated leaking source from a valve manifold box (VMB) for 5 or 10min, respectively. Three Fourier transform infrared spectrometers (FTIRs) were simultaneously used to measure the spatial and temporal distributions of SF_6 concentrations. The measured data were then compared with the numerical results and the agreement is seen to be quite good. From the numerical results, the pollutant hot spots, peak pollutant concentration at the end of leaking, and time taken for the concentration to reduce to near background level are obtained.
机译:在这项研究中进行了工作风扇过滤器单元(FFU)洁净室中流场和浓度场的数值模拟和实验测量。该研究的目的是找出泄漏的气体污染物的不稳定浓度分布。标准K-ε模型用于流场模拟。为了获得气体浓度场,将一定浓度的SF_6气体作为模拟泄漏源分别从阀门总管箱(VMB)释放5分钟或10分钟。同时使用三个傅立叶变换红外光谱仪(FTIR)来测量SF_6浓度的时空分布。然后将测得的数据与数值结果进行比较,发现一致性非常好。根据数值结果,可以获得污染物热点,泄漏结束时的峰值污染物浓度以及浓度降低到接近背景水平所需的时间。