High-intensity focused ultrasound (HIFU) treatment is a promising non-invasive method for killing or destroying the diseased tissues by locally delivering thermal and mechanical energy without damaging surrounding normal tissues. In HIFU, measuring the temperature at the site of delivery is important for improving therapeutic efficacy, controlling safety, and appropriately planning a treatment. Several researchers have proposed photoacoustic thermometry for monitoring HIFU treatment, but they had many limitations, including the inability to image while the HIFU is on, inability to provide two-dimensional monitoring, and the inability to be used clinically. In this paper, we propose a novel integrated real-time photoacoustic thermometry system for HIFU treatment monitoring. The system provides ultrasound B-mode imaging, photoacoustic structural imaging, and photoacoustic thermometry during HIFU treatment in real-time for both in vitro and in vivo environments, without any interference from the strong therapeutic HIFU waves. We have successfully tested the real-time photoacoustic thermometry by investigating the relationship between the photoacoustic amplitude and the measured temperature with in vitro phantoms and in vivo tumor-bearing mice. The results show the feasibility of a real-time photoacoustic thermometry system for safe and effective monitoring of HIFU treatment.
机译:高强度聚焦超声(HIFU)治疗是一种有前途的无创方法,可通过局部传递热能和机械能而不会破坏周围的正常组织来杀死或破坏患病的组织。在HIFU中,测量分娩部位的温度对于提高治疗效果,控制安全性和适当计划治疗很重要。几位研究人员已经提出了用于监测HIFU治疗的光声测温法,但是它们有很多局限性,包括HIFU开启时无法成像,无法提供二维监测以及无法在临床上使用。在本文中,我们提出了一种用于HIFU治疗监测的新型集成实时光声测温系统。该系统可在HIFU治疗期间针对体外和体内环境实时提供超声B型成像,光声结构成像和光声测温,而不受强治疗性HIFU波的干扰。通过研究体外体模和体内荷瘤小鼠的光声振幅与测得的温度之间的关系,我们已经成功地测试了实时光声测温法。结果表明了实时光声测温系统对HIFU治疗的安全有效监测的可行性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号