首页> 外文期刊>Australasian physical & engineering sciences in medicine >BIOLOGICAL EQUIVALENT UNIFORM DOSE VERSUS DOSE VOLUME CONSTRAINTS IN INTENSITY MODULATED RADIOTHERAPY PLAN OPTIMISATION
【24h】

BIOLOGICAL EQUIVALENT UNIFORM DOSE VERSUS DOSE VOLUME CONSTRAINTS IN INTENSITY MODULATED RADIOTHERAPY PLAN OPTIMISATION

机译:强度等效的放射治疗计划优化中,生物等效剂量剂量对剂量体积的约束

获取原文
获取原文并翻译 | 示例
           

摘要

The results indicated that the EUD-based optimisation parameter 'a' spans in a useful range between -3 to 3 when tested in the clinical cases. The use of EUD-based optimisation can effectively reduce the number of constraints in both the simple and complex planning volumes. The EUD-based constraint is particularly useful for the parallel organs such as the parotid in the head and neck case. In this case the objective can easily be satisfied with EUD-based constraint and the plan optimisation is also faster when compared to the dose-volume based constraint optimisation. The EUD-based optimisation is a useful planning tool. It creates more flexibility by adding another degree of freedom in the IMRT planning process.
机译:结果表明,在临床案例中进行测试时,基于EUD的优化参数'a'介于-3到3之间。使用基于EUD的优化可以有效地减少简单和复杂计划量中的约束数量。基于EUD的约束对于平行器官(例如头颈部病例中的腮腺)特别有用。在这种情况下,与基于剂量-体积的约束优化相比,基于EUD的约束可以轻松满足目标,并且计划优化也更快。基于EUD的优化是有用的计划工具。通过在IMRT计划过程中增加另一个自由度,可以提高灵活性。

著录项

  • 来源
  • 作者

    Thuc Pham; Shan Yau; Sean White;

  • 作者单位

    Nepean Cancer Care Centre, Sydney West Area Health Service, Sydney, Australia Institute of Medical Physics, School of Physics, University of Sydney, Australiarn;

    Nepean Cancer Care Centre, Sydney West Area Health Service, Sydney, Australia;

    Nepean Cancer Care Centre, Sydney West Area Health Service, Sydney, Australia;

  • 收录信息
  • 原文格式 PDF