首页> 外文期刊>ATW >Effect of chloride transients on the corrosion behaviour of low alloyed steel in cladding flaws of reactor pressure vessels under oxygenated high-temperature water conditions
【24h】

Effect of chloride transients on the corrosion behaviour of low alloyed steel in cladding flaws of reactor pressure vessels under oxygenated high-temperature water conditions

机译:氯化物瞬态对氧化高温水条件下反应堆压力容器覆层缺陷中低合金钢腐蚀行为的影响

获取原文
获取原文并翻译 | 示例
           

摘要

In den letzten Jahren wurde bei Untersuchungen zum Korrosionsverhalten niedriglegierter Stähle (LAS) unter oxidie-renden Hochtemperaturwasserbedingungen (HTW) festgestellt, dass auch geringe Mengen von Chloriden eine Er-höhung der Risswachstumsgeschwin-digkeit in LAS bewirken können. Ein neues Untersuchungsprogramm wurde aufgelegt, um dieses Ergebnis zu bewerten. In Leichtwasserreaktoren bestehen Komponenten des Primärkreises aus LAS. Mediumberührte Oberflächen sind mit austenitischen Schweißplattierungen als Korrosionsschutz versehen. Im Fall von potenziell durchgehenden Plattie-rungsfehlern, welche Bestandteil von rechnerischen Sicherheitsnachweisen sind, hätte das Primärkühlmittel direkten Kontakt mit dem darunter liegenden LAS. Da derartige Plattierungsfehler als schmale Spalte anzunehmen sind, wäre die Zusammensetzung des Mediums am Fehlergrund anders, als die des umgebenden Kühlmittels. Im vorliegenden Beitrag werden erstmalig detaillierte Bewertungen zur Wasserchemie in einem Plattierungsfehler vorgestellt. Es wurde festgestellt, dass das Redoxpotential am Fehlergrund deutlich geringer ist, als das für HTW-Bedingungen typische und dass sich die Chloridkonzentration im Fehlervolumen um den Faktor 30 erhöht. Für die Untersuchungen wurde der Reaktordruckbehälterstahl 20MnMo-Ni55 verwendet. Die Untersuchungen haben ergeben, dass Chloridtransienten bis zu 50 ppb im Kühlmittel eine Erhöhung des Chlo-ridgehalts auf 1.500 ppb im Volumen eines Plattierungsfeh-lers bedeuten können. Dabei wurde die wichtige Erkenntnis gewonnen, dass sich selbst dieser Chloridgehalt nicht negativ auf das Korrosionsverhalten von LAS innerhalb von Plattierungsfehlern auswirkt.%Strain-induced corrosion cracking in low alloy steels (LAS) has been extensively investigated during the last decades. One finding from recent investigations is the detrimental role of even small amounts of chlorides, which has been shown to increase the cracking susceptibility of LAS. In order to evaluate this finding a demanding research programme has been established. In light water reactor plants, the pressure vessel and in some cases also the piping is made of LAS, covered with welded stainless steel cladding for improved corrosion protection. In structural failure assessments of primary circuits, penetrating cladding flaws have to be assumed, which could locally expose the underlying LAS to the cooling water. Due to the narrow opening of such weld defects the aqueous solution in contact with the underlying LAS would have a different composition from that of the bulk cooling water. In this paper, first detailed calculations of the water chemistry prevailing in such conditions revealed that oxygen concentration decreases rapidly when going from the mouth of the cladding flaw towards the bottom, bringing the redox potential to values, much lower than those typical for oxygenated high temperature water (HTW). Also, chloride was found to en-rich into the cladding flaw volume by a factor of x30. The material studied was 20MnMoNi55 used for the reactor coolant line of a German NPP. Based on the results obtained, it can be concluded that chloride transients up to 50 ppb in the bulk HTW, resulting in an enrichment of chloride in a penetrating cladding flaw up to 1,500 ppb, do not result in any serious consequences for the corrosion of LAS at the bottom of the cladding flaw.
机译:近年来,对低合金钢(LAS)在氧化高温水条件(HTW)下的腐蚀行为的研究发现,即使少量的氯化物也会导致LAS裂纹扩展率的提高。启动了新的调查程序以评估此结果。在轻水反应堆中,一次回路的组件由LAS组成。与介质接触的表面设有奥氏体焊接镀层,以防腐蚀。如果存在潜在的连续电镀错误(这是计算安全性证据的一部分),则主冷却液将直接与下面的LAS接触。由于可以将这种电镀缺陷假定为狭窄的间隙,因此缺陷底部的介质成分将与周围冷却液的成分不同。在本文中,首次提出了电镀错误中水化学的详细评估。发现故障原因处的氧化还原电势明显低于HTW条件下的典型氧化还原电势,并且故障体积中的氯化物浓度增加了30倍。反应堆压力容器钢20MnMo-Ni55用于研究。研究表明,冷却剂中氯化物瞬变高达50 ppb可能意味着电镀误差量中氯化物含量增加到1,500 ppb。重要的发现是,即使在电镀误差内,氯化物含量也不会对LAS的腐蚀行为产生负面影响。在过去的几十年中,对低合金钢(LAS)中的应变诱发的腐蚀开裂进行了广泛的研究。最近的一项研究发现,即使少量的氯化物也具有有害作用,已显示出这种作用会增加LAS的开裂敏感性。为了评估这一发现,已经建立了苛刻的研究计划。在轻水反应堆工厂中,压力容器以及某些情况下的管道由LAS制成,并用焊接的不锈钢包层覆盖,以提高防腐性能。在一次回路的结构失效评估中,必须假设有穿透性的包层缺陷,这可能会使底层的LAS局部暴露在冷却水中。由于这种焊接缺陷的狭窄开口,与下面的LAS接触的水溶液的成分将与大体积冷却水的成分不同。在本文中,首先对这种情况下普遍存在的水化学进行了详细的计算,结果表明,当氧从包层缺陷的口部向底部移动时,氧浓度会迅速降低,从而使氧化还原电势达到比氧化高温典型值低的值水(HTW)。因此,发现氯化物富集到包层缺陷体积中是x30。研究的材料是20MnMoNi55,用于德国NPP的反应堆冷却剂管线。根据获得的结果,可以得出结论:散装HTW中高达50 ppb的氯化物瞬态,导致高达1500 ppb的穿透性覆层缺陷中的氯化物富集,不会对LAS的腐蚀造成任何严重后果在覆层缺陷的底部。

著录项

  • 来源
    《ATW》 |2014年第4期|221-227214216|共9页
  • 作者单位

    Department of Physical Chemistry University of Chemical Technology and Metallurgy 8 St.Kliment Ohridski Blvd 1756 Sofia/Bulgaria;

    E.ON Kernkraft GmbH Tresckowstr.5 30457 Hannover Hanover/Germany;

    E.ON Kernkraft GmbH Tresckowstr.5 30457 Hannover Hanover/Germany;

    VTT Materials and Building VTT Technical Research Centre of Finland P.O.Box 1000 02044 VTT,Espoo/Finland;

  • 收录信息 美国《科学引文索引》(SCI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号