首页> 外文期刊>Atmospheric environment >Performance evaluation of the active-flow personal DataRAM PM_(2.5) mass monitor (Thermo Anderson pDR-1200) designed for continuous personal exposure measurements
【24h】

Performance evaluation of the active-flow personal DataRAM PM_(2.5) mass monitor (Thermo Anderson pDR-1200) designed for continuous personal exposure measurements

机译:专为连续个人暴露测量而设计的有源流量个人DataRAM PM_(2.5)质量监测器(Thermo Anderson pDR-1200)的性能评估

获取原文
获取原文并翻译 | 示例
           

摘要

The need for continuous personal monitoring for exposure to particulate matter has been demonstrated by recent health studies showing effects of PM exposure on time scales of less than a few hours. Filter-based methods cannot measure this short-term variation of PM levels, which can be quite significant considering human activity patterns. The goal of this study was to evaluate the active-flow personal DataRAM for PM_(2.5) (MIE pDR-1200; Thermo Electron Corp., Franklin, MA) designed as a wearable monitor to continuously measure particle exposure. The instrument precision was found to be good (2.1%) and significantly higher than the passive pDR configuration tested previously. A comparison to other proven continuous monitors resulted in good agreement at low relative humidities. Results at higher humidity followed predictable trends and provided a correction scheme that improved the accuracy of pDR readings. The pDR response to particle size also corresponded to previously observed and theoretical errors. The active flow feature of the pDR allows collection of the sampled particles on a back-up filter. The 24-h mass measured on this filter was found to compare very well with a Federal Reference Method for PM_(2.5) mass.
机译:最近的健康研究表明,需要进行连续的个人监测以监测颗粒物质的暴露,表明PM暴露在少于几个小时的时间范围内。基于过滤器的方法无法测量这种PM水平的短期变化,考虑到人类活动模式,这可能非常重要。这项研究的目的是评估PM_(2.5)的有效流量个人DataRAM(MIE pDR-1200;马萨诸塞州富兰克林的Thermo Electron Corp.),将其设计为可穿戴式监测器,以连续测量颗粒暴露。发现仪器精度良好(2.1%),远高于先前测试的被动pDR配置。与其他久经考验的连续监测仪相比,在较低的相对湿度下具有良好的一致性。较高湿度下的结果遵循可预测的趋势,并提供了一种校正方案,可以提高pDR读数的准确性。 pDR对粒径的响应也对应于先前观察到的和理论误差。 pDR的主动流动功能可将采样的颗粒收集在备用过滤器上。发现在此过滤器上测量的24小时质量与PM_(2.5)质量的联邦参考方法相当好。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号