首页> 外文期刊>Atmospheric environment >Temporal considerations in the measurement of indoor mass transfer coefficients
【24h】

Temporal considerations in the measurement of indoor mass transfer coefficients

机译:室内传质系数测量中的时间因素

获取原文
获取原文并翻译 | 示例
           

摘要

Indoor pollutant mass transport, characterized by the "transport-limited deposition velocity", v(t), is dynamic and measurements of this mass-transfer coefficient can be influenced by changing conditions. We find that for large, but realistic, changes in indoor transport conditions during the sampling period, time-averaged measurements of v(t) can be in error by 40% or more. Measurements using a highly surface reactive species, such as nitric acid, incur the greatest error. The measurement error incurred for species that are moderately surface reactive, such as ozone, varies depending on the type of surfaces available for deposition. Further, the greater the magnitude and frequency in the fluctuations, the greater the error anticipated from time-averaged measurements of vt. An analysis of continuous flux measurements from field experiments in apartments, a lab and an office suggest that time-averaged measurements of v(t) will typically be in error by 5-15%. (c) 2006 Elsevier Ltd. All rights reserved.
机译:室内污染物的大规模运输具有动态性,其特征在于“运输受限的沉积速度” v(t),并且该传质系数的测量会受到条件变化的影响。我们发现,对于采样期间内室内运输条件的较大但现实的变化,v(t)的时间平均测量值可能会误差40%或更多。使用高表面活性物质(例如硝酸)进行测量会产生最大的误差。具有中等表面反应性的物种(例如臭氧)引起的测量误差取决于可用于沉积的表面类型。此外,波动的幅度和频率越大,根据vt的时间平均测量值所预期的误差就越大。来自公寓,实验室和办公室的现场实验的连续通量测量结果分析表明,v(t)的时间平均测量值通常会有5-15%的误差。 (c)2006 Elsevier Ltd.保留所有权利。