首页> 外文期刊>ASHRAE Transactions >Experimental Comparison of Pressure Loss in Typical Flexible and Sheet Metal Residential Duct Systems
【24h】

Experimental Comparison of Pressure Loss in Typical Flexible and Sheet Metal Residential Duct Systems

机译:典型的柔性和钣金住宅风管系统中压力损失的实验比较

获取原文
获取原文并翻译 | 示例
           

摘要

Tests were performed to measure airflow characteristics of properly installed multibranch duct systems composed of wire-wound flexible ducts and rigid sheet metal ducts. When flexible duct systems were not sized per applicable standards required to design residential duct systems, the total system pressure loss penalty was as much as 44% when expressed in terms of the measured system loss coefficients. However, the difference in pressure loss for typical residential duct systems constructed from properly sized wire-wound flexible ducts and similar systems constructed from rigid steel ducts was negligible at design conditions.
机译:进行了测试,以测量正确安装的多分支管道系统的气流特性,该系统由绕线柔性管道和刚性钣金管道组成。如果未按照设计民用风管系统所需的适用标准来确定挠性风管系统的尺寸,则以测得的系统损耗系数表示时,系统总压力损失损失高达44%。但是,在设计条件下,由适当尺寸的绕线挠性风管构成的典型住宅风管系统与由刚性钢质风管构成的类似系统的压力损失差异可忽略不计。

著录项

  • 来源
    《ASHRAE Transactions》 |2018年第2期|102-115|共14页
  • 作者

    A. Paruchuri; S. Idem;

  • 作者单位

    Department of Mechanical Engineering at Tennessee Tech University, Cookeville, TN, USA;

    Department of Mechanical Engineering at Tennessee Tech University, Cookeville, TN, USA;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng