首页> 外文期刊>Applied Surface Science >Characterization of anodized titanium for hydrometallurgical applications-Evidence for the reduction of cupric on titanium dioxide
【24h】

Characterization of anodized titanium for hydrometallurgical applications-Evidence for the reduction of cupric on titanium dioxide

机译:湿法冶金用阳极氧化钛的表征-二氧化钛上铜还原的证据

获取原文
获取原文并翻译 | 示例
           

摘要

Anodic oxide films (AOFs) were potentiostatically formed on commercially pure titanium in 0.5 M sulfuric acid solutions at various anodizing voltages (up to 80 V) at room temperature. The subject of this study was the corrosion resistance of the AOFs in synthetic copper sulfide leaching solutions containing 30 glr1 sulfuric acid as well as 12gL~(-1) Cl~-, 15gL~(-1) Cu~(2+) and 1 gL~(-1) Fe~(3+). Open circuit potential (OCP) measurement, linear polarization resistance (LPR) and electrochemical impedance spectroscopy (EIS) were used to study the corrosion response of the AOFs in copper sulfide leaching solutions up to 85 ℃. Scanning electron microscopy (SEM) was used to investigate the morphology of the AOFs before and after 12 h of immersion at 85 ℃. X-ray photoelectron spectroscopy (XPS) was used to examine the surface chemistry of the AOFs after immersion. OCP measurements showed that the final failure of the AOFs occurred in 2 h in de-aerated 30gL~(-1) H_2SO_4 and 12gL~(-1) Cl~- solutions at 85 ℃ Both LPR and EIS results showed a significant increase in the corrosion resistance of the anodized titanium versus that of freshly polished titanium. Electrochemical results were confirmed by SEM analysis, where the AOF formed at 80 V lead to the best improvement in corrosion resistance. XPS measurements revealed that Cu~(2+) was reduced to Cu or Cu~+ within the titanium oxide film. It was further confirmed that the presence of leaching oxidants would inhibit the reduction of Cu~(2+) on titanium dioxide in chloride containing copper sulfide leaching solutions.
机译:在室温下,在各种阳极氧化电压(最高80 V)下,在0.5 M硫酸溶液中的商用纯钛上恒电位形成阳极氧化膜(AOF)。这项研究的主题是AOF在含有30 glr1硫酸以及12gL〜(-1)Cl〜-,15gL〜(-1)Cu〜(2+)和1的合成硫化铜浸出液中的耐腐蚀性。 gL〜(-1)Fe〜(3+)。用开路电势(OCP),线性极化电阻(LPR)和电化学阻抗谱(EIS)研究了高达85℃的硫化铜浸出溶液中AOF的腐蚀响应。扫描电镜(SEM)研究了在85℃下浸泡12小时前后AOF的形态。 X射线光电子能谱(XPS)用于检查浸没后AOF的表面化学性质。 OCP测量表明,在85℃下,脱气的30gL〜(-1)H_2SO_4和12gL〜(-1)Cl〜-溶液中AOF的最终失效发生在2小时内,LPR和EIS结果均显示出阳极氧化的钛与刚抛光的钛的耐腐蚀性。电化学结果通过SEM分析得到证实,其中在80 V时形成的AOF导致耐腐蚀性的最佳提高。 XPS测量表明,在氧化钛膜中Cu〜(2+)被还原为Cu或Cu〜+。进一步证实,在含氯化物的硫化铜浸出液中,浸出氧化剂的存在会抑制二氧化钛上Cu〜(2+)的还原。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号