首页> 外文期刊>IEEE Transactions on Applied Superconductivity >Charging test results of the DPC-TJ, a high-current-density large superconducting coil for fusion machines
【24h】

Charging test results of the DPC-TJ, a high-current-density large superconducting coil for fusion machines

机译:高电流密度大型聚变机超导线圈DPC-TJ的充电测试结果

获取原文
获取原文并翻译 | 示例
           

摘要

The authors describe the electromagnetic results and the quench phenomena of the DPC-TJ large cable-in-conduit Nb/sub 3/Sn coil experiment which took place in the summer of 1991. The DPC-TJ coil was developed by Toshiba and JAERI in collaboration to demonstrate the realization of (NbTi)/sub 3/Sn superconducting coils for fusion with high average current density of 40 A/mm/sup 2/. The coil was charged up to its rated current of 24 kA (40 A/mm/sup 2/) at 7.6 T without quench in the DPC test facility. Thereafter, the electromagnetic performance was tested by measuring I/sub c/ and T/sub cs/, and the critical current at 12 T was estimated to be 41 kA. The quench phenomena of the DPC-TJ coil were also tested by measuring normal-zone propagation velocity to get the protection design. In these experiments, very slow and very fast propagation were observed. Many other electromagnetic results were also obtained, which are necessary for the design of fusion machines such as International Thermonuclear Experimental Reactor.
机译:作者介绍了1991年夏天进行的DPC-TJ大型导管内Nb / sub 3 / Sn线圈实验的电磁结果和淬火现象。合作演示了实现(NbTi)/ sub 3 / Sn超导线圈用于熔融的平均电流密度为40 A / mm / sup 2 /的实现。在DPC测试设备中,线圈在7.6 T下被充电至其额定电流24 kA(40 A / mm / sup 2 /),而没有淬火。之后,通过测量I / sub c /和T / sub cs /来测试电磁性能,并且在12 T时的临界电流估计为41 kA。还通过测量正常区域传播速度来测试DPC-TJ线圈的失超现象,以得到保护设计。在这些实验中,观察到非常慢和非常快的传播。还获得了许多其他电磁结果,这对于设计聚变机器(例如国际热核实验反应堆)是必需的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号