首页> 外文期刊>Applied Physics Letters >Biotin-streptavidin detection with a graphene-oxide supported radio-frequency resonator
【24h】

Biotin-streptavidin detection with a graphene-oxide supported radio-frequency resonator

机译:石墨烯支持的射频共振器检测生物素-链霉亲和素

获取原文
获取原文并翻译 | 示例
           

摘要

The detection of biotin-streptavidin binding was demonstrated by the resonance frequency measurement of a simple resonance circuit using graphene oxide dielectric. The resonance frequency was decreased to the lower frequency range as biotin and streptavidin were bound to the graphene oxide film. Graphene oxide dielectric provides dual advantages including quality-factor enhancement and high affinity for bio sensing. It was revealed that an increase in capacitance of the graphene oxide sheet was mainly responsible for the resonance frequency shift. The sensitivity to the capacitance change in the frequency-based detection technique can enable the advanced biosensing applications using graphene oxide sheet.
机译:通过使用氧化石墨烯电介质的简单谐振电路的谐振频率测量,证明了生物素-链霉亲和素结合的检测。由于生物素和抗生蛋白链菌素结合到氧化石墨烯膜上,共振频率降低到较低的频率范围。氧化石墨烯电介质具有双重优势,包括质量因子增强和对生物传感的高亲和力。已经发现,氧化石墨烯片的电容的增加主要是引起共振频率偏移的原因。基于频率的检测技术对电容变化的敏感性可使使用氧化石墨烯片的先进生物传感应用成为可能。

著录项

  • 来源
    《Applied Physics Letters》 |2013年第19期|193701.1-193701.4|共4页
  • 作者单位

    Department of Mechanical Engineering, Yonsei University, Seoul 120-749, South Korea;

    Department of Mechanical Engineering, Yonsei University, Seoul 120-749, South Korea;

    Samsung Advanced Institute of Technology, Yongin 446-712, South Korea;

    Samsung Advanced Institute of Technology, Yongin 446-712, South Korea;

    Samsung Advanced Institute of Technology, Yongin 446-712, South Korea;

    Department of Mechanical Engineering, Yonsei University, Seoul 120-749, South Korea;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);