首页> 外文期刊>IEEE Antennas & Propagation Magazine >A practical millimeter-wave radar calibration target
【24h】

A practical millimeter-wave radar calibration target

机译:实用的毫米波雷达校准目标

获取原文
获取原文并翻译 | 示例
           

摘要

A simple rectangular-plate millimeter-wave radar calibration target gives RCS values ranging from hundreds to thousands of square meters. This enable tests over extended ranges and with equipment having modest output power. Precise mechanical alignment mechanisms and an optical sight are mandatory, due to the narrow beamwidth. Absorber collars provide an easy way of adjusting the actual RCS according to specific mission requirements, and effectively reduce edge-diffraction effects. The measured V-band calibration uncertainty was less than 0.5 dB, and the pointing resolution was better than 0.05°.
机译:一个简单的矩形板毫米波雷达标定目标可提供数百到数千平方米的RCS值。这样可以在扩展范围内以及具有中等输出功率的设备上进行测试。由于光束宽度较窄,因此必须有精确的机械对准机构和瞄准镜。吸收环提供了一种根据特定任务要求调整实际RCS的简便方法,并有效降低了边缘衍射效应。测量的V波段校准不确定度小于0.5 dB,指向分辨率优于0.05°。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号