...
首页> 外文期刊>Analytical and Bioanalytical Chemistry >Development of an ultrasensitive immunochromatography test to detect nicotine metabolites in oral fluids
【24h】

Development of an ultrasensitive immunochromatography test to detect nicotine metabolites in oral fluids

机译:用于检测口腔液中尼古丁代谢物的超灵敏免疫色谱测试方法的开发

获取原文
获取原文并翻译 | 示例
           

摘要

Passive exposure to tobacco smoke causes a variety of illnesses ranging from allergic responses to cancer. Assessment of exposure to second-hand tobacco smoke (SHS), particularly among vulnerable populations enables intervention and prevention of future disease. A minimally invasive oral fluids-based onsite test to detect such exposure would create a valuable tool for researchers and clinicians. Here we describe the development of a test that uses an inexpensive reader that utilizes a CMOS image sensor to reliably quantify a reporter signal and determine nicotine exposure. The rapid lateral flow test consists of a nitrocellulose strip with a control line containing goat anti-rabbit IgG, used as an internal standard, and a test line containing BSA–cotinine conjugate. To run the test, diluted sample containing antibodies against cotinine, the major metabolite of nicotine, is mixed with protein A–gold nanoparticles and placed on the sample pad. As the sample runs up to the nitrocellulose pad, antibodies in the running buffer bind to available cotinine. If cotinine is absent, the antibodies will bind to the BSA–cotinine derivative immobilized on the test line, resulting in an intense purple–red band. The concentration of cotinine equivalents in the sample can be estimated from interpretation of the test line. In this article we describe the effect of different cotinine derivatives, oral fluid pretreatment, and application and running buffers on assay sensitivity. The test can reliably detect as little as 2 ng mL−1 cotinine equivalents. The assay is sensitive, simple, rapid, inexpensive, and easily implementable in point-of-care facilities to detect second-hand smoke exposure.
机译:被动接触烟草烟雾会导致多种疾病,从过敏反应到癌症。评估二手烟(SHS)的暴露量,尤其是在脆弱人群中的暴露量,可以干预和预防未来疾病。基于微创口腔液体的现场测试以检测此类接触,将为研究人员和临床医生创造有价值的工具。在这里,我们描述了使用便宜的阅读器进行测试的过程,该阅读器利用CMOS图像传感器来可靠地量化报告信号并确定尼古丁暴露量。快速侧向流动测试由硝酸纤维素试纸和含有内标的山羊抗兔IgG对照线和含有BSA-可卡因共轭物的测试线组成。为了进行测试,将含有抗可替宁抗体(尼古丁的主要代谢产物)的稀释样品与A蛋白-金纳米颗粒混合,并置于样品垫上。当样品流向硝酸纤维素垫时,运行缓冲液中的抗体会与可用的可替宁结合。如果不存在可替宁,抗体将与固定在测试线上的BSA-可卡因衍生物结合,形成一条强烈的紫红色条带。样品中可替宁当量的浓度可以通过测试线的解释来估算。在本文中,我们描述了不同可替宁衍生物,口服液的预处理以及应用和运行缓冲液对测定灵敏度的影响。该测试可以可靠地检测出低至2 ng mL -1 可替宁当量。该检测方法灵敏,简单,快速,廉价且易于在现场护理设施中实施,以检测二手烟暴露。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号