...
首页> 外文期刊>Analytical and Bioanalytical Chemistry >Comparison of solid phase microextraction and hollow fiber liquid phase microextraction for the determination of pesticides in aqueous samples by gas chromatography triple quadrupole tandem mass spectrometry
【24h】

Comparison of solid phase microextraction and hollow fiber liquid phase microextraction for the determination of pesticides in aqueous samples by gas chromatography triple quadrupole tandem mass spectrometry

机译:固相微萃取与中空纤维液相微萃取气相色谱三重串联四极杆串联质谱法测定水样中农药的比较

获取原文
获取原文并翻译 | 示例
           

摘要

This work compares two miniaturised sample preparation methods, solid phase microextraction (SPME) and hollow fiber liquid phase microextraction (HF-LPME), in combination with gas chromatography coupled to tandem mass spectrometry with a triple quadrupole analyzer for the determination of 77 pesticides in drinking water. In the case of SPME, extraction temperature and time were optimized by experimental design, although other parameters, as desorption time, pH, and ionic strength, were also evaluated. The extraction and desorption solvents [octanol/dihexyl ether (75:25, v/v) and cyclohexane, respectively], as well as the extraction and desorption time, ionic strength, and pH, were studied for the HF-LPME procedure. Under the optimal conditions, recoveries (70.2–113.5% for SPME and 70.0–119.5% for HF-LPME), intra-day precision (2.1–19.4% for SPME and 4.3–22.5% for HF-LPME), inter-day precision (5.2–21.5% for SPME and 8.4–27.3% for HF-LPME), and limits of detection, between 0.1 and 28.8 ng/L for SPME and 0.2 and 47.1 ng/L for HF-LPME and overall uncertainty (9.6–25.2% for SPME and 13.3–27.5% for HF-LPME) were established for both extraction procedures. Finally, the proposed methods were successfully applied to the analysis of 41 drinking water samples, and similar results were obtained with both extraction approaches.
机译:这项工作比较了两种微型化的样品制备方法,固相微萃取(SPME)和中空纤维液相微萃取(HF-LPME),结合气相色谱-串联质谱联用三重四极杆分析仪,用于测定饮用水中的77种农药水。对于SPME,通过实验设计优化了萃取温度和时间,尽管还评估了其他参数,如解吸时间,pH和离子强度。研究了用于HF-LPME程序的萃取和脱附溶剂[分别为辛醇/二己醚(75:25,v / v)和环己烷],以及萃取和脱附时间,离子强度和pH。在最佳条件下,日内精度(SPME为70.2–113.5%,HF-LPME为70.0–119.5%),日内精度(SPME为2.1–19.4%和HF-LPME为4.3–22.5%),日间精度(SPME为5.2–21.5%,HF-LPME为8.4–27.3%),检出限为:SPME为0.1至28.8 ng / L,HF-LPME为0.2至47.1 ng / L,总不确定度(9.6–25.2对于两种萃取程序,均确定了SPME的%和HF-LPME的13.3–27.5%。最后,将所提出的方法成功应用于41种饮用水样品的分析,两种提取方法均获得了相似的结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号