The thrust of the dielectric barrier discharge plasma actuator is the plasma body force minus the wall shear force, and it equals the net induced momentum. Thrust measurement simplicity makes it a good metric of the aerodynamic performance for active flow control applications. Uncertainty and non-repeatability issues with conventional test setups motivated development of a novel suspended actuator test setup and a measurement methodology consisting of a burn-in procedure followed by frequency scans at constant voltages. This approach led to observation of negative values of thrust, or antithrust, at low frequencies between 4Hz and up to 64Hz. The antithrust is proportional to the mean-squared voltage and is frequency independent. Departures from the parabolic antithrust curve are correlated with appearance of visible plasma discharges. The antithrust hypothesis is proposed. It states that the measured thrust is the sum of plasma thrust and antithrust. The magnitude of the antithrust depends on the actuator geometry, the materials, and the test installation. The dependence on test installation was validated by surrounding the actuator with a grounded large-diameter metal sleeve. A thrust data correction for antithrust enables meaningful comparisons between actuators at different installations. A strong dependence on humidity is also shown. The thrust significantly decreases with increasing humidity.
机译:介质阻挡放电等离子体致动器的推力是等离子体体力减去壁剪切力,它等于净感应动量。推力测量的简便性使其成为主动流量控制应用中空气动力学性能的良好度量。常规测试装置的不确定性和不可重复性问题推动了新型悬架执行器测试装置和测量方法的开发,该方法包括老化程序,然后在恒定电压下进行频率扫描。这种方法导致在4Hz至64Hz的低频下观察到负推力或反推力的负值。防推力与均方电压成比例,并且与频率无关。抛物线抗推力曲线的偏离与可见的等离子体放电的出现相关。提出了反推力假设。它指出测得的推力是等离子推力和反推力的总和。防推力的大小取决于执行器的几何形状,材料和测试装置。通过用大直径接地的金属套管包围执行器来验证对测试安装的依赖性。防推力的推力数据校正可以对不同安装位置的执行器进行有意义的比较。还显示出对湿度的强烈依赖性。推力随着湿度的增加而显着降低。

著录项

  • 来源
    《AIAA Journal》 |2017年第12期|4181-4192|共12页
  • 作者单位

    NASA, John H Glenn Res Ctr, 21000 Brookpark Rd, Cleveland, OH 44135 USA;

    HX5 Sierra LLC, 21000 Brookpark Rd, Cleveland, OH 44135 USA;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号