Previous studies have shown that the stress concentration factors for 90 degrees square hollow section T- and X-joints can be significantly reduced by filling the chord with concrete and stiffening the chord with perfobond ribs. The current study examined stress concentration factors for non-90 degrees (Y-type) joints. A total of 11 Y-joints were tested under axial tension, and the hot spot stresses were measured. The measured results were employed to evaluate the influence of design parameters on the stress concentrations. In addition, the measured results were used to evaluate finite element models. A parametric study was then undertaken using the finite element models to generate an extensive database of stress concentration factors and to develop parametric design equations to estimate the maximum stress concentration factors on the brace and the chord of concrete-filled square hollow section Y-joints with perfobond ribs. It was found that decreases of 13.7%-59.9% in the stress concentration factors occurred in concrete-filled square hollow section Y-joints stiffened by perfobond ribs relative to conventional square hollow section joints for different loading cases.
机译:先前的研究表明,通过在弦中填充混凝土并用perfobond肋加强弦,可以显着降低90度方形空心截面T型和X型接头的应力集中系数。当前的研究检查了非90度(Y型)关节的应力集中系数。在轴向张力下总共测试了11个Y型接头,并测量了热点应力。测量结果用于评估设计参数对应力集中的影响。此外,测量结果还用于评估有限元模型。然后使用有限元模型进行参数研究,以生成广泛的应力集中系数数据库,并开发参数设计方程式,以估计方钢管混凝土空心截面Y型节点的支撑和弦上的最大应力集中系数。肋骨。研究发现,在不同的荷载情况下,用perbonbond筋加固的方型空心空心Y型节点相对于传统的方形空心型节节点,应力集中系数降低了13.7%-59.9%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号