A dual anode electron gun has been designed using EGUN for Ku-band 140W short length space Traveling Wave Tube (TWT). Pierce type electron gun with an electrically isolated beam forming electrode (BFE), a control anode and an ion barrier anode (A0) in addition to ground has been opted. Due considerations have been given in the design of gun assembly to ensure the long life (>10 years) and high reliability. A PPM circuit with confined beam flow focusing has also been designed with Sm2Co17 magnets using inhouse developed code MAGFLD. A good beam laminarity and beam ripples (<5%) have been obtained. An electron gun assembly has been designed and developed with due considerations for high voltage and thermal considerations from space TWT point of view.
机译:使用EGUN设计的双阳极电子枪用于Ku波段140W短长度太空行波管(TWT)。选择了带有接地的电隔离束形成电极(BFE),控制阳极和离子阻挡阳极(A0)的Pierce型电子枪。在喷枪组件的设计中已适当考虑,以确保使用寿命长(> 10年)和高可靠性。还使用内部开发的代码MAGFLD设计了带有约束束流聚焦的PPM电路和Sm2Co17磁体。获得了良好的光束层流度和光束波动(<5%)。在设计和开发电子枪组件时,从空间TWT的角度考虑了高压和热因素。