首页> 外文期刊>ACI Structural Journal >Punching Shear Strength of Flat Slab-Edge Column Connections with Outward Eccentricity of Loading
【24h】

Punching Shear Strength of Flat Slab-Edge Column Connections with Outward Eccentricity of Loading

机译:平板平板边缘圆柱连接的冲切抗剪强度与荷载向外偏心

获取原文
获取原文并翻译 | 示例
           

摘要

Thirteen tests were carried out to investigate the effect of outwards eccentricity on the punching resistance of flat slab edge column connections. The slabs measured 2350 × 1700 mm (92.5 × 66.9 in.) on plan and were 180 mm (7.1 in.) thick. One end of the slab was supported on a 300 mm (11.8 in.) square column with a boot at its base for imposition of eccentricity. The other end was supported on a fixed roller support that extended across the full slab width of 1700 mm (66.9 in.). Four point loads were applied to the unsupported slab edges. The tested variables were eccentricity and the areas of flexural, shear, and torsion reinforcement. Presented test results include reinforcement strains, displacements, rotations, crack patterns, failure modes, and ultimate loads. The ACI 318 design procedure for punching shear at edge columns with outwards eccentricity is shown to be overly conservative unless the interaction between punching shear and unbalanced moment is reduced as permitted by the code. The EC2 design procedure is unsatisfactory and a modification is proposed.
机译:进行了十三项测试,以研究向外偏心率对平板平板边柱连接的抗冲孔性的影响。这些平板的平面图尺寸为2350×1700毫米(92.5×66.9英寸),厚为180毫米(7.1英寸)。平板的一端支撑在300毫米(11.8英寸)的方形柱上,底部有一个防尘套,用于施加偏心。另一端支撑在固定的滚轴支架上,该支架在整个板坯宽度1700毫米(66.9英寸)上延伸。四点载荷被施加到不受支撑的板边缘。测试的变量是偏心率以及抗弯,抗剪和抗扭的面积。给出的测试结果包括钢筋应变,位移,旋转,裂纹模式,破坏模式和极限载荷。除非规范允许减少冲剪与不平衡力矩之间的相互作用,否则ACI 318的设计方法在偏心向外的边缘柱上冲剪时,显示的方法过于保守。 EC2的设计程序不理想,并提出了修改方案。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号