首页> 美国卫生研究院文献>Membranes >Pilot-Scale Assessment of Urea as a Chemical Cleaning Agent for Biofouling Control in Spiral-Wound Reverse Osmosis Membrane Elements
【2h】

Pilot-Scale Assessment of Urea as a Chemical Cleaning Agent for Biofouling Control in Spiral-Wound Reverse Osmosis Membrane Elements

机译:尿素作为化学清洗剂用于螺旋缠绕反渗透膜元件生物污损控制的中试评估

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Routine chemical cleaning with the combined use of sodium hydroxide (NaOH) and hydrochloric acid (HCl) is carried out as a means of biofouling control in reverse osmosis (RO) membranes. The novelty of the research presented herein is in the application of urea, instead of NaOH, as a chemical cleaning agent to full-scale spiral-wound RO membrane elements. A comparative study was carried out at a pilot-scale facility at the Evides Industriewater DECO water treatment plant in the Netherlands. Three fouled 8-inch diameter membrane modules were harvested from the lead position of one of the full-scale RO units treating membrane bioreactor (MBR) permeate. One membrane module was not cleaned and was assessed as the control. The second membrane module was cleaned by the standard alkali/acid cleaning protocol. The third membrane module was cleaned with concentrated urea solution followed by acid rinse. The results showed that urea cleaning is as effective as the conventional chemical cleaning with regards to restoring the normalized feed channel pressure drop, and more effective in terms of (i) improving membrane permeability, and (ii) solubilizing organic foulants and the subsequent removal of the surface fouling layer. Higher biomass removal by urea cleaning was also indicated by the fact that the total organic carbon (TOC) content in the HCl rinse solution post-urea-cleaning was an order of magnitude greater than in the HCl rinse after standard cleaning. Further optimization of urea-based membrane cleaning protocols and urea recovery and/or waste treatment methods is proposed for full-scale applications.
机译:结合使用氢氧化钠(NaOH)和盐酸(HCl)进行常规化学清洁,作为反渗透(RO)膜中生物污垢控制的一种方法。本文提出的研究的新颖性在于将尿素而不是氢氧化钠作为化学清洁剂应用于全尺寸螺旋缠绕式反渗透膜元件。在荷兰的Evides Industriewater DECO水处理厂的中试规模的工厂进行了比较研究。从处理膜生物反应器(MBR)渗透液的满量程反渗透装置之一的引导位置收获了三个污损的8英寸直径膜组件。未清洁一个膜组件,并作为对照。通过标准的碱/酸清洁方案清洁第二个膜组件。第三膜组件用浓尿素溶液清洗,然后酸洗。结果表明,就恢复归一化进料通道的压降而言,尿素清洗与常规化学清洗一样有效,并且在以下方面更有效:(i)改善膜渗透性,(ii)增溶有机污垢物并随后除去表面结垢层。通过尿素清洗后的HCl清洗溶液中的总有机碳(TOC)含量比标准清洗后的HCl清洗大一个数量级,这也表明了通过尿素清洗获得的更高的生物量去除率。对于全面应用,提出了进一步优化基于尿素的膜清洁方案以及尿素回收和/或废物处理方法的建议。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号