摘要

The authors describe a modification of the instrumental parameters of the Diamat fully automated HPLC system for Hb A2 assay (Bio-Rad Laboratories, Milan, Italy) in order to obtain simultaneous determination of Hb A2 and Hb F.Hb A2 and Hb F measurements are reproducible (within-run CV 2.6%, with Hb A22.7%; 5.1%, with Hb F 1.3%) and accurate (from a comparison with two microchromatographic techniques for Hb A2: r = 0.9639 and 0.9755; with two alkali denaturation procedures for Hb F: r = 0.9990 and 0.9952; with radial immunodiffusion, r = 0.9877). Assay linearity has been confirmed for Hb A2 concentrations between 0 and 6.0%, and for Hb F between 0 and 60%. The data obtained from the analysis of some pathological samples for Hb Bart's, Hb H, Hb J Sardegna, Hb Lepore and Hb S are in agreement with cellulose acetate electrophoresis analysis.The Hb A2 reference intervals for normals (N = 597) and Beta-thalassemia carriers (N = 200) are respectively (95% limits) 2.02-3.27 and 3.92-5.90 in % units. Hb F values measured in normals (N = 968), in β-thal carriers (N = 302) andin δβ-thal carriers (N =3) have been found to be consistent withthe usual diagnostic parameters.Some minor limitations emerged: the most relevant concerns HbA1c, which is overestimated with respect to a reference method (y =1.217x + 0.16; N = 79; r = 0.9235). A probable interferencefrom labile fractions is responsible for this Hb A1c inaccuracy.
机译:作者描述了Diamat全自动HPLC系统用于Hb A2测定的仪器参数的修改(Bio-Rad Laboratories,Milan,Italy),以便同时测定Hb A2和Hb F.Hb A2和Hb F测量是可重现(内部CV为2.6%,Hb A22.7%; 5.1%,Hb F 1.3%)和准确的(与Hb A2的两种微色谱技术比较:r = 0.9639和0.9755;采用两种碱变性程序对于Hb F:r = 0.9990和0.9952;采用放射免疫扩散,r = 0.9877)。 Hb A2浓度在0%至6.0%之间,Hb F在0%至60%之间时,测定线性已得到确认。通过对某些病理样本进行Hb Bart's,Hb H,Hb J Sardegna,Hb Lepore和Hb S分析获得的数据与醋酸纤维素电泳分析相符。正常人群(N = 597)和Beta-地中海贫血携带者(N = 200)的百分比单位分别为(2.05%-2-3%)和2.02-3.27和3.92-5.90%。 Hb F值在法线(N = 968),β-thal携带者(N = 302)和已发现δβ-thal载流子(N = 3)中的通常的诊断参数。出现一些较小的局限性:最相关的问题HbA1c,相对于参考方法(y =1.217x + 0.16; N = 79; r = 0.9235)。可能的干扰不稳定馏分中的杂质是造成Hb A1c不准确的原因。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号