The value of tibial mounted inertial measurement units to quantify running kinetics in elite football (soccer) players. A reliability and agreement study using a research orientated and a clinically orientated system

机译:胫骨惯性测量单元的价值用于量化足球(足球)运动员的跑步动力学。使用研究导向型和临床导向型系统的可靠性和一致性研究

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

In elite football, measurement of running kinetics with inertial measurement units (IMUs) may be useful as a component of periodic health examination (PHE). This study determined the reliability of, and agreement between a research orientated IMU and clinically orientated IMU system for initial peak acceleration (IPA) and IPA symmetry index (SI) measurement during running in elite footballers. On consecutive days, 16 participants performed treadmill running at 14kmph and 18kmph. Both IMUs measured IPA and IPA SI concurrently. All measurements had good or excellent within-session reliability (intraclass correlation coefficient (ICC2,1) range = 0.79–0.96, IPA standard error of measurement (SEM) range = 0.19–0.62 g, IPA SI SEM range = 2.50–8.05%). Only the research orientated IMU demonstrated acceptable minimal detectable changes (MDCs) for IPA at 14kmph (range = 7.46–9.80%) and IPA SI at both speeds (range = 6.92–9.21%). Considering both systems, between-session IPA reliability ranged from fair to good (ICC2,1 range = 0.63–0.87, SEM range = 0.51–1.10 g) and poor to fair for IPA SI (ICC2,1 range = 0.32–0.65, SEM range = 8.07–11.18%). All MDCs were >10%. For IPA and SI, the 95% levels of agreement indicated poor between system agreement. Therefore, the use of IMUs to evaluate treadmill running kinetics cannot be recommended in this population as a PHE test to identify prognostic factors for injuries or for rehabilitation purposes.
机译:在精英足球中,使用惯性测量单位(IMU)进行跑步动力学的测量可用作定期健康检查(PHE)的一部分。这项研究确定了以研究为导向的IMU和临床为导向的IMU系统的可靠性,并在精英足球运动员跑步过程中测量初始峰值加速度(IPA)和IPA对称指数(SI)之间达成了共识。在连续的几天中,有16名参与者以14kmph和18kmph的速度跑步。两个IMU同时测量IPA和IPA SI。所有测量均具有良好或出色的会话可靠性(类内相关系数(ICC2,1)范围= 0.79-0.96,IPA标准测量误差(SEM)范围= 0.19-0.62 g,IPA SI SEM范围= 2.50-8.05%) 。只有以研究为导向的IMU证明了在两种速度下IPA在14kmph(范围= 7.46-9.80%)和IPA SI时都可接受的最小可检测变化(MDC)(范围= 6.92-9.21%)。考虑到这两个系统,会话间IPA可靠性的范围从中等到良好(ICC2,1范围= 0.63–0.87,SEM范围= 0.51–1.10 g),而对于IPA SI(ICC2,1范围= 0.32–0.65,SEM范围= 8.07–11.18%)。所有MDC均> 10%。对于IPA和SI,协议级别的95%表示系统协议之间的协议级别很低。因此,在该人群中不建议使用IMU来评估跑步机的运行动力学,作为PHE测试来确定受伤或康复目的的预后因素。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号