首页> 美国卫生研究院文献>The Iowa Orthopaedic Journal >Nine Year Follow-up of a Ceramic-on-Ceramic Bearing Total Hip Arthroplasty Utilizing a Layered Monoblock Acetabular Component
【2h】

Nine Year Follow-up of a Ceramic-on-Ceramic Bearing Total Hip Arthroplasty Utilizing a Layered Monoblock Acetabular Component

机译:使用分层整体式髋臼假体的陶瓷-陶瓷轴承全髋关节置换术的九年随访。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

IntroductionEarly ceramic bearing systems in total hip arthoplasty (THA) sought to provide long term wear improvement over traditional metal on polyethylene systems. However, previous designs exhibited fractures of the ceramic acetabular liner, leading to the development of the Implex Hedrocel ceramic bearing THA system where the ceramic liner was supported on a layer of polyethylene intended to transition liner loads to the metal shell, a so-called “sandwich” design. Unfortunately, the device trial was stopped to further enrollment when liner fractures were reported. The current study examines nearly 10-year follow-up on 28 devices implanted by two surgeons at one institution in order to document ceramic bearing system performance over a longer time period.
机译:简介全髋关节置换术(THA)中的早期陶瓷轴承系统试图提供比传统金属聚乙烯系统更好的长期耐磨性。但是,以前的设计显示出髋臼陶瓷内衬破裂,从而导致了Implex Hedrocel陶瓷轴承THA系统的发展,该系统将陶瓷内衬支撑在一层聚乙烯上,以将内衬载荷转移到金属壳上,即所谓的“三明治”设计。不幸的是,当有衬管破裂的报道时,该装置的试验被停止,以进一步招募。当前的研究检查了由两位外科医生在一个机构植入的28种器械进行了近10年的随访,以记录陶瓷轴承系统在较长时间内的性能。