Halitosis is defined as a foul odor emanated from the oral cavity, with great impact in quality of life and social restraints. Recently, the use of Breath Alert™ in research increased significantly. Halimeter™, another portable device, is often used in clinical practice. Nevertheless, not many studies have verified the accuracy and compared the results of both devices simultaneously. Objective: To verify the accuracy of Breath Alert™ and Halimeter™ in patients without chief complaint of halitosis, using the organoleptic test (OT) as "gold standard." The second aim was to verify whether their concomitant use could enhance the diagnostic accuracy of halitosis. Material and Methods: A cross-sectional analytical study was performed. The quality of expired air of 34 subjects without chief complaint of halitosis was assessed. Two experienced examiners carried out the OT. Afterward, a third blinded examiner performed Halimeter™ (HT) and Breath Alert™ (BA) tests. Results: The OT identified halitosis in 21 subjects (62%). The area under the ROC curve (95% confidence interval) was 0.67 (0.48-0.85) and 0.54 (0.34-0.75) for HT and BA, respectively. The accuracy for HT and BA was 59% and 47%, respectively. The combined usage of HT and BA provided 11 positive results, being 9 subjects (43%) out of the total of 21 positive cases. Conclusions: Halimeter™ and Breath Alert™ were not able to diagnose halitosis in non-complainer subjects at the same level as the organoleptic examination, since their accuracy were low. Our results suggest that such portable devices are not reliable tools to assess halitosis and may neglect or misdiagnose a considerable number of patients in clinical practice.
机译:口臭是指从口腔中散发出的恶臭,对生活质量和社会约束有很大影响。最近,在研究中使用Breath Alert™的人数大大增加。 Halimeter™是另一种便携式设备,通常在临床实践中使用。然而,很少有研究证实了准确性并同时比较了两种设备的结果。目的:使用感官测试(OT)作为“金标准”,以验证Breath Alert™和Halimeter™在没有主要口臭的患者中的准确性。第二个目的是验证它们的同时使用是否可以提高口臭的诊断准确性。材料和方法:进行了横截面分析研究。评估了34名没有口臭的主诉者的呼出空气质量。 OT由两名经验丰富的审查员完成。之后,第三位盲人检查员进行了Halimeter™(HT)和Breath Alert™(BA)测试。结果:OT鉴定出21名受试者的口臭(62%)。 HT和BA的ROC曲线下面积(95%置信区间)分别为0.67(0.48-0.85)和0.54(0.34-0.75)。 HT和BA的准确度分别为59%和47%。 HT和BA的联合使用提供了11例阳性结果,占21例阳性病例中的9例(43%)。结论:Halimeter™和Breath Alert™无法以与感官检查相同的水平诊断非抱怨者的口臭,因为它们的准确性很低。我们的结果表明,这种便携式设备不是评估口臭的可靠工具,在临床实践中可能会忽略或误诊大量患者。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号