A 56-year-old female patient with significant carotid stenoses with circumferential plaques, causing localized vascular narrowing, was inappropriately indicated for carotid artery stenting. After placement of a distal embolic protection device in the left internal carotid artery, a stent was inserted; however, it could not be fully deployed due to the rigid, severely calcified vascular walls. The various endovascular attempts to recapture the protection device were futile and, eventually, led to fracture of the guidewire of the device and it remained entrapped together with the stent. Emergency carotid arteriotomy with extirpation of the stent and embolic protection device via carotid thromboendarterectomy was performed. In conclusion, the proper patient selection for carotid artery stenting is of utmost importance.
机译:一个56岁的女性患者,具有重要颈动脉的颈部有明显的颈斑,导致局部血管变窄,对于颈动脉支架不恰当地表明。在左内部颈动脉中放置远端栓塞装置后,插入支架;但是,由于刚性,严重钙化的血管壁,它无法完全部署。重新捕获保护装置的各种血管内尝试是徒劳的,最终导致装置的导丝的骨折,它保持夹在一起。进行急诊颈动脉动脉,通过颈动脉血栓术治疗支架和栓塞保护装置的剥落。总之,颈动脉支架的适当患者选择至关重要。