首页> 美国卫生研究院文献>The Surgery Journal >Successful Reimplantation of Spinal Cord Stimulator One Year after Device Removal Due to Infection
【2h】

Successful Reimplantation of Spinal Cord Stimulator One Year after Device Removal Due to Infection

机译:脊髓刺激器的成功再植入脊髓刺激器在饲料引起的感染后一年内删除

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Spinal cord stimulation is an effective treatment modality for patients with numerous pain conditions. Although proven to be highly successful, device implantation does come with some inherent risks. One of the most challenging complications is perioperative infection. For most patients, a simple trial of oral antibiotics and in-office drainage of any superficial infectious material may be sufficient. Deeper infections with wound dehiscence necessitate device removal and intravenous antibiotic therapy. The question remains, if the device was previously providing pain relief for the patient, when is the appropriate time to reimplant the device after the infection has cleared? We describe the case of explantation of an infected device and successful reimplantation after 1 year.
机译:脊髓刺激是患者患者患者的有效治疗方式。虽然被证明是非常成功的,但设备植入确实存在一些固有的风险。最具挑战性的并发症之一是围手术期感染。对于大多数患者,口服抗生素和任何浅表传染性物质的口腔抗生素的简单试验可能就足够了。伤口裂缝的深入感染需要装置去除和静脉抗生素治疗。问题仍然存在,如果设备以前为患者提供了疼痛缓解,则在感染清除后适当的时间重新涂抹该装置?我们描述了在1年后促进受感染的设备和成功再造林的情况。