Background: The number of voids within the root canal obturation is a relevant parameter to describe the quality of the technique, as well as to predict long-term prognosis. The aim of this study was to evaluate the quality of root canal obturation in curved root canals filled with Thermafil, GuttaCore, GuttaFusion and lateral compaction with AH Plus and EndoSequence BC sealer, by means of percentage of gutta-percha and sealer filled area. Methods: 200 curved canals of mandibular molars were divided in five groups (n = 40). Each specimen was evaluated at 3, 6 and 9 mm from the apex. A total of 600 samples were analyzed. Obturation was performed with either Thermafil (TH), GuttaCore (GC), GuttaFusion (GF) or lateral compaction (LC), using AH Plus as sealer. In another group EndoSequence BC sealer (BC) was used. Subgroups (n = 20) were made depending on the use of sonic activation during the placement of the sealer. The percentage of total obturation material was analyzed as an indirect measurement of percentage of voids. Results: GF showed a better performance at the apical level, while GC showed the higher percentage of total obturation at the coronal area. No differences were observed for the activation of sealers in any of the groups. Statistical analysis was performed by using two-way ANOVA. Statistical significance was set at CI: 95% (p < 0.05). Conclusions: Sonic activation of sealers did not show any benefit to avoid the presence of voids within obturation of curved canals. Following the manufacturer recommendations, we found that TH did not show benefits when applied to curved canals.
机译:背景:根管闭锁内的空隙数是描述技术质量的相关参数,以及预测长期预后。本研究的目的是评估含有Thermafil,Guttacore,Guttafusion和横向压实的弯曲根部管中的根管闭塞质量,通过Gutta-Percha和封口填充区域的百分比百分比。方法:将200个弯曲的下颌臼齿分为五组(n = 40)。从顶点的3,6和9mm评估每个样品。分析了总共600个样品。密闭用任一热软化(TH),GuttaCore(GC),GuttaFusion(GF)或横向压实(LC)进行的,使用AH加上作为密封剂。在另一组中,使用胆管性BC封口剂(BC)。根据在封口器的放置期间使用声波激活来进行亚组(n = 20)。分析了总收闭物质的百分比作为间接测量空隙百分比的百分比。结果:GF在顶点显示出更好的性能,而GC在冠状区显示出较高的总闭电百分比。在任何组中的密封剂中没有观察到差异。使用双向ANOVA进行统计分析。统计显着性设定为CI:95%(P <0.05)。结论:密封剂的声波激活没有显示出任何有益的益处,以避免在弯曲的运河溶胀中存在空隙。遵循制造商的建议,我们发现当应用于弯曲的运河时,TH没有显示好处。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号