Adsorptive stripping voltammetric determination of Tetracycline in pharmaceutical capsule formulation using Poly(Malachite green) modified glassy carbon electrode

机译:使用聚(孔雀石绿色)改性玻碳电极对药物胶囊制剂中四环素的吸附剥离伏安测定

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

A selective and sensitive electrochemical method based on glassy carbon electrode modified with poly(malachite green) was developed for determination of tetracycline in pharmaceutical capsule formulation. Cyclic voltammetry and electrochemical impedance spectroscopy using [Fe(CN)6]3-/4- as a probe were used to characterize the potentiodynamiclly deposited poly(malachite green) on the surface of glassy carbon electrode. In contrast to the unmodified glassy carbon electrode, the fabricated poly(malachite green) modified glassy carbon electrode showed catalytic property towards two steps irreversible oxidation of tetracycline. Better correlation of the oxidative peak current with the scan rate than with the square root of scan rate supported by slope of 0.60 for log(current) versus log(scan rate) indicated that the oxidation reaction of tetracycline at the modified electrode was predominantly controlled by electron exchange step at the solution polymer interface. Under optimized solution pH, and accumulation parameters, the square wave adsorptive anodic striping peak current response of the modified electrode showed linear dependence on concentration of tetracycline in the range 5–100 μM with determination coefficient, method detection limit, and quantification limit of 0.99588, 1.6 μM, and 5.3 μM, respectively. The tetracycline content of a capsule sample claimed to have 250 mg/capsule was found to be 250.53 mg/capsule with 0.21% deviation. Excellent spike recovery result of 99.80%, and 98.49–99.78% recovery of tetracycline in capsule sample in the presence of 50–200% of UA, AA, and ampicillin validated the applicability of the method for determination of tetracycline in real samples with complex matrix like capsule formulations.
机译:基于聚(孔雀石绿色)改性的基于玻碳碳电极的选择性和敏感的电化学方法,用于测定药物胶囊配方中的四环素。使用[Fe(CN)6] 3- / 4-作为探针的循环伏安和电化学阻抗光谱用于表征玻碳电极表面上的电位上沉积的聚(孔雀石绿)。与未改性的玻碳电极相反,制造的聚(孔雀石绿色)改性玻璃电极显示出致催化性能朝向四环素不可逆氧化的两个步骤。氧化峰值电流与扫描速率的相比比用0.60的斜率为0.60的扫描速率的平方根相关性,而LOG(扫描速率)表明修饰电极在改性电极处的四环素的氧化反应主要由在溶液聚合物界面处的电子交换步骤。在优化的溶液pH和累积参数下,改性电极的方波吸附阳极条纹峰值电流响应显示线性依赖性对四环素的浓度为5-100μm,测定系数,方法检测极限和0.99588的量化限制,分别为1.6μm和5.3μm。要求保护的胶囊样品的四环素含量具有250mg /胶囊,是250.53mg /胶囊,偏差0.21%。优异的尖峰恢复结果为99.80%,98.49-99.78%在UA,AA和氨苄青霉素的50-200%存在下胶囊样品在胶囊样品中恢复的98.49-99.78%验证了该方法在具有复杂基质的真实样品中测定四环素的适用性像胶囊配方一样。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号