The amount of energy necessary to place an implant in its seat, described as the integral of the torque-depth curve at insertion (I), has been validated as a reliable measure of primary stability. This study aimed to investigate whether (I) may detect the variations in primary stability caused by changes in the implant length or diameter better than the insertion torque (IT). Cylindric implants featuring a double-etched, sandblasted surface with different diameters or lengths were placed into monolithic polyurethane foam blocks with different densities that mimicked human bone. (I)-, (I)*-, IT-, IT*-diameter and -length plots ((I)* and IT* were the derived values corrected for undersizing) were drawn and the relation between (I), (I)*, IT, and IT* and the fixture diameter or length was investigated with correlation analysis. (I)* and IT* correlated better than (I) and IT with the fixture diameter; (I), (I)*, IT, and IT* correlated equally well with the fixture length. In all cases, the slopes of the lines best fitting the experimental data were greater for (I) or (I)* than IT or IT*, respectively. (I) or (I)* were better detectors than IT or IT* of the changes in primary stability that can be achieved by increasing the fixture diameter or length.
机译:将植入物放置在其底座中所需的能量(在插入处(I)处表示为扭矩-深度曲线的积分)已被验证为可靠的主要稳定性指标。这项研究旨在调查(I)是否可以比植入扭矩(IT)更好地检测到由植入物长度或直径变化引起的初级稳定性变化。将具有不同直径或长度的双蚀刻,喷砂表面的圆柱型植入物放入具有不同密度的整体式聚氨酯泡沫块中,以模仿人体骨骼。绘制(I)-,(I)*-,IT-,IT *-直径和长度图((I)*和IT *是为减小尺寸而校正的导出值),并绘制了(I),(I )*,IT和IT *以及夹具直径或长度进行相关分析。 (I)*和IT *与夹具直径的相关性优于(I)和IT (I),(I)*,IT和IT *与灯具长度的相关性相同。在所有情况下,最适合实验数据的直线的斜率(I)或(I)*分别大于IT或IT *。 (I)或(I)*是比IT或IT *更好的检测器,它可以通过增加夹具直径或长度来实现一次稳定性的变化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号