首页> 美国卫生研究院文献>Sensors (Basel Switzerland) >The Coefficient of Variation of Step Time Can Overestimate Gait Abnormality: Test-Retest Reliability of Gait-Related Parameters Obtained with a Tri-Axial Accelerometer in Healthy Subjects
【2h】

The Coefficient of Variation of Step Time Can Overestimate Gait Abnormality: Test-Retest Reliability of Gait-Related Parameters Obtained with a Tri-Axial Accelerometer in Healthy Subjects

机译:步进时间的变化系数可能会高估步态异常:在健康受试者中使用三轴加速度计获得的步态相关参数的重测可靠性

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The aim of this study was to investigate whether variation in gait-related parameters among healthy participants could help detect gait abnormalities. In total, 36 participants (21 men, 15 women; mean age, 35.7 ± 9.9 years) performed a 10-m walk six times while wearing a tri-axial accelerometer fixed at the L3 level. A second walk was performed ≥1 month after the first (mean interval, 49.6 ± 7.6 days). From each 10-m data set, the following nine gait-related parameters were automatically calculated: assessment time, number of steps, stride time, cadence, ground force reaction, step time, coefficient of variation (CV) of step time, velocity, and step length. Six repeated measurement values were averaged for each gait parameter. In addition, for each gait parameter, the difference between the first and second assessments was statistically examined, and the intraclass correlation coefficient (ICC) was calculated with the level of significance set at < 0.05. Only the CV of step time showed a significant difference between the first and second assessments ( = 0.0188). The CV of step time also showed the lowest ICC, at <0.50 (0.425), among all parameters. Test–retest results of gait assessment using a tri-axial accelerometer showed sufficient reproducibility in terms of the clinical evaluation of all parameters except the CV of step time.
机译:这项研究的目的是调查健康参与者中步态相关参数的变化是否可以帮助检测步态异常。总共有36名参与者(21名男性,15名女性;平均年龄35.7±9.9岁)佩戴了固定在L3水平的三轴加速度计,进行了10米步行六次。第一次步行≥1个月后进行第二次步行(平均间隔49.6±7.6天)。从每个10米的数据集中,自动计算出以下9个与步态相关的参数:评估时间,步数,步幅时间,节奏,地面力反作用,步长时间,步长变化系数(CV),速度,和步长。将每个步态参数的六个重复测量值取平均值。此外,对于每个步态参数,统计检查第一次评估和第二次评估之间的差异,并在显着性水平设置为<0.05的情况下计算组内相关系数(ICC)。在第一个和第二个评估之间,只有步长时间的CV显示出显着差异(= 0.0188)。在所有参数中,步进时间的CV还显示出最低的ICC,<0.50(0.425)。使用三轴加速度计进行步态评估的重测结果显示,除了步长CV外,所有参数的临床评估都具有足够的可重复性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号