首页> 美国卫生研究院文献>Journal of Veterinary Diagnostic Investigation : Official Publication of the American Association of Veterinary Laboratory Diagnosticians Inc >Validation of a spectrophotometric method for GGT measurement in canine urine and determination of the urine GGT-to-creatinine ratio reference interval and biological variation in 41 healthy dogs
【2h】

Validation of a spectrophotometric method for GGT measurement in canine urine and determination of the urine GGT-to-creatinine ratio reference interval and biological variation in 41 healthy dogs

机译:分光光度法测定犬尿中GGT的含量以及确定41只健康犬尿GGT与肌酐比值的参考区间和生物学变异的方法的验证

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The urine gamma-glutamyl transferase (GGT)-to-creatinine ratio has been used to monitor patients at risk of acute renal injury. We validated the spectrophotometric quantification of GGT in urine in a commercial biochemistry analyzer. The assay was precise, accurate, and linear. Intra-assay precision was 3.59% in 4 samples, with GGT concentrations of 47–195 U/L. Inter-assay precision in 3 samples with activities of 11–51 U/L was 7.74%. Accuracy was 97.3%, with an absolute bias of 2.7 U/L. Urine GGT was unaffected by hematuria, hemoglobinuria, or bacteriuria. Urine GGT was stable at 20°C and 4°C for up to 3 d. Storage by freezing at −20°C resulted in a significant reduction in enzyme activity. A pH outside the range of 6.5–8 resulted in reduced GGT activity. The biological variation of urine GGT-to-creatinine ratio provided an index of individuality of 1.6, indicating that a population-based reference interval (RI) can be used. The reference change value was calculated, and an increase in consecutive measurements >43% is required to be regarded as significant. The urine GGT-to-creatinine ratio RI obtained in a population of 41 healthy dogs was 8.5–28.5 U/g.
机译:尿γ-谷氨酰转移酶(GGT)与肌酐的比率已用于监测有急性肾损伤风险的患者。我们在商用生物化学分析仪中验证了尿液中GGT的分光光度定量。该测定是精确,准确和线性的。 4个样品的测定内精密度为3.59%,GGT浓度为47–195 U / L。 3个活性为11–51 U / L的样品的批间精密度为7.74%。准确性为97.3%,绝对偏差为2.7 U / L。尿GGT不受血尿,血红蛋白尿或细菌尿的影响。尿GGT在20°C和4°C的温度下稳定3dd。通过在-20°C下冷冻保存,酶活性显着降低。 pH值超出6.5–8会导致GGT活性降低。尿液GGT与肌酐比值的生物学变化提供了1.6的个性指数,表明可以使用基于人群的参考区间(RI)。计算了参考变化值,必须将连续测量值的增加> 43%视为显着。在41只健康犬中获得的尿GGT与肌酐之比RI为8.5-28.5 U / g。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号