首页> 美国卫生研究院文献>Journal of Clinical Medicine >Comparison between Micro-Computed Tomography and Cone-Beam Computed Tomography in the Assessment of Bone Quality and a Long-Term Volumetric Study of the Augmented Sinus Grafted with an Albumin Impregnated Allograft
【2h】

Comparison between Micro-Computed Tomography and Cone-Beam Computed Tomography in the Assessment of Bone Quality and a Long-Term Volumetric Study of the Augmented Sinus Grafted with an Albumin Impregnated Allograft

机译:微计算机断层扫描技术与锥形束计算机断层扫描技术在评估骨质量以及对白蛋白浸润的同种异体移植鼻窦进行长期体积研究方面的比较

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The purpose of our study was to compare micromorphometric data obtained by cone-beam computed-tomography (CBCT) and microcomputed-tomography (micro-CT) of the augmented sinus and to evaluate the long-term stability of the bone gain achieved using BoneAlbumin. Sinus lifts, and after 6-months, healing bone-biopsy and implant placement were carried out. Specimens were analyzed by micro-CT. A total of 16 samples were collected from nine patients (mean age 54.7 ± 6.5 years). Pre-, postoperative, and 3-year control CBCT-data were registered to determine from where the biopsy samples were harvested. Micromorphometric variables were calculated from the micro-CT- and CBCT-data, and their correlation was determined by Spearman’s test. The volume of augmented bone was calculated at the time of implant placement and after 3 years. A positive correlation was found between bone-volume fraction, trabecular-separation, open-, and total-porosity, while a negative correlation was found between trabecular-thickness obtained from CBCT- and micro-CT-data ( < 0.05). Mean volumetric reduction of 39.28% (11.88–60.02%) was observed. Correlation of CBCT- and micro-CT-data suggested that micromorphometric analysis of CBCT reconstructions of the augmented sinuses provided reliable information on the microarchitecture of augmented bone. CBCT as a modality might be adequate in the analysis of bone quality in the augmented sinus. At the 3-year, control sinus grafts showed volumetric stability.
机译:我们研究的目的是比较通过锥窦计算机断层扫描(CBCT)和微计算机断层扫描(micro-CT)所获得的增强窦的显微形态学数据,并评估使用BoneAlbumin获得的骨增益的长期稳定性。窦抬高,六个月后,进行愈合的骨活检和植入物植入。通过显微CT分析标本。从9名患者(平均年龄54.7±6.5岁)中收集了16个样本。记录术前,术后和3年对照的CBCT数据,以确定从何处收集活检样本。从微观CT和CBCT数据计算出微观形态变量,并通过Spearman检验确定其相关性。在植入植入物时和3年后计算骨的增加量。骨体积分数,小梁分离,开孔和总孔隙度之间呈正相关,而从CBCT和微CT数据获得的小梁厚度之间呈负相关(<0.05)。平均体积减少了39.28%(11.88–60.02%)。 CBCT数据与微CT数据的相关性表明,对增强窦的​​CBCT重建进行微观形态分析可提供有关增强骨微结构的可靠信息。 CBCT作为一种方式可能足以分析增强窦的骨质。在3年时,对照窦移植物显示出体积稳定性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号