首页> 美国卫生研究院文献>Journal of Clinical Microbiology >Impact of Human Immunodeficiency Virus Type 1 (HIV-1) Genetic Diversity on Performance of Four Commercial Viral Load Assays: LCx HIV RNA Quantitative AMPLICOR HIV-1 MONITOR v1.5 VERSANT HIV-1 RNA 3.0 and NucliSens HIV-1 QT
【2h】

Impact of Human Immunodeficiency Virus Type 1 (HIV-1) Genetic Diversity on Performance of Four Commercial Viral Load Assays: LCx HIV RNA Quantitative AMPLICOR HIV-1 MONITOR v1.5 VERSANT HIV-1 RNA 3.0 and NucliSens HIV-1 QT

机译:人类免疫缺陷病毒1型(HIV-1)遗传多样性对四种商业病毒载量分析性能的影响:LCx HIV RNA定量AMPLICOR HIV-1 MONITOR v1.5VERSANT HIV-1 RNA 3.0和NucliSens HIV-1 QT

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Human immunodeficiency virus type 1 (HIV-1) evolution and changing strain distribution present a challenge to nucleic acid-based assays. Reliable patient monitoring of viral loads requires the detection and accurate quantification of genetically diverse HIV-1. A panel of 97 HIV-1-seropositive plasma samples collected from Cameroon, Brazil, and South Africa was used to compare the performance of four commercially available HIV RNA quantitative tests: Abbott LCx HIV RNA Quantitative assay (LCx), Bayer Versant HIV-1 RNA 3.0 (bDNA), Roche AMPLICOR HIV-1 MONITOR v1.5 (Monitor v1.5), and bioMérieux NucliSens HIV-1 QT (NucliSens). The panel included group M, group O, and recombinant viruses based on sequence analysis of gag p24, pol integrase, and env gp41. The LCx HIV assay quantified viral RNA in 97 (100%) of the samples. In comparison, bDNA, Monitor v1.5, and NucliSens quantified viral RNA in 96.9%, 94.8%, and 88.6% of the samples, respectively. The two group O specimens were quantified only by the LCx HIV assay. Analysis of nucleotide mismatches at the primer/probe binding sites for Monitor v1.5, NucliSens, and LCx assays revealed that performance characteristics reflected differences in the level of genetic conservation within the target regions.
机译:人类1型免疫缺陷病毒(HIV-1)的进化和菌株分布的变化对基于核酸的检测提出了挑战。要对患者的病毒载量进行可靠的监测,就需要检测和准确定量遗传上不同的HIV-1。从喀麦隆,巴西和南非收集的一组97个HIV-1血清阳性血浆样本用于比较四种市售的HIV RNA定量测试的性能:雅培LCx HIV RNA定量测定法(LCx),拜耳Versant HIV-1 RNA 3.0(bDNA),罗氏AMPLICOR HIV-1 MONITOR v1.5(显示器v1.5)和bioMérieuxNucliSens HIV-1 QT(NucliSens)。小组包括M组,O组和基于gag p24,pol整合酶和env gp41的序列分析的重组病毒。 LCx HIV检测定量了97个样本(100%)中的病毒RNA。相比之下,bDNA,Monitor v1.5和NucliSens分别在96.9%,94.8%和88.6%的样品中定量了病毒RNA。 O组的两个标本仅通过LCx HIV分析进行定量。对Monitor v1.5,NucliSens和LCx分析的引物/探针结合位点处的核苷酸错配进行分析,发现性能特征反映了目标区域内遗传保守水平的差异。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号