首页> 美国卫生研究院文献>Journal of Clinical Microbiology >Methicillin-Resistant Staphylococcus aureus: Comparison of Susceptibility Testing Methods and Analysis of mecA-Positive Susceptible Strains
【2h】

Methicillin-Resistant Staphylococcus aureus: Comparison of Susceptibility Testing Methods and Analysis of mecA-Positive Susceptible Strains

机译:耐甲氧西林金黄色葡萄球菌:药敏试验方法的比较和mecA阳性药敏菌株的分析

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Methicillin-resistant Staphylococcus aureus (MRSA) is responsible for an increasing number of serious nosocomial and community-acquired infections. Phenotypic heterogeneous drug resistance (heteroresistance) to antistaphylococcal beta-lactams affects the results of susceptibility testing. The present study compared the MRSA-Screen latex agglutination test (Denka Seiken Co., Ltd., Tokyo, Japan) for detection of PBP 2a with agar dilution, the VITEK-1 and VITEK-2 systems (bioMérieux, St. Louis, Mo.), and the oxacillin agar screen test for detection of MRSA, with PCR for the mecA gene used as the “gold standard” assay. Analysis of 107 methicillin-susceptible S. aureus (MSSA) isolates and 203 MRSA isolates revealed that the MRSA-Screen latex agglutination test is superior to any single phenotype-based susceptibility testing method, with a sensitivity of 100% and a specificity of 99.1%. Only one isolate that lacked mecA was weakly positive by the MRSA-Screen latex agglutination test. This isolate was phenotypically susceptible to oxacillin and did not contain the mecA gene by Southern blot hybridization. The oxacillin agar screen test, the VITEK-1 system, the VITEK-2 system, and agar dilution showed sensitivities of 99.0, 99.0, 99.5, and 99%, respectively, and specificities of 98.1, 100, 97.2, and 100%, respectively. The differences in sensitivity or specificity were not statistically significant. Oxacillin bactericidal assays showed that mecA- and PBP 2a-positive S. aureus isolates that are susceptible to antistaphylococcal beta-lactams by conventional methods are functionally resistant to oxacillin. We conclude that the accuracy of the MRSA-Screen latex agglutination method for detection of PBP 2a approaches the accuracy of PCR and is more accurate than any susceptibility testing method used alone for the detection of MRSA.
机译:耐甲氧西林金黄色葡萄球菌(MRSA)导致越来越多的严重医院和社区获得性感染。表型对抗葡萄球菌β-内酰胺类药物的耐药性(异抗性)影响药敏试验的结果。本研究比较了MRSA-Screen乳胶凝集试验(Denka Seiken Co.,Ltd.,日本东京)用琼脂稀释液,VITEK-1和VITEK-2系统(bioMérieux,圣路易斯,密苏里州)检测PBP 2a的情况。 ),以及用于检测MRSA的奥沙西林琼脂筛选试验,并将用于mecA基因的PCR用作“黄金标准”试验。对107种甲氧西林敏感金黄色葡萄球菌(MSSA)分离株和203种MRSA分离株的分析表明,MRSA-Screen乳胶凝集试验优于任何一种基于表型的敏感性试验方法,灵敏度为100%,特异性为99.1% 。通过MRSA-Screen乳胶凝集试验,只有一个缺少mecA的分离株呈弱阳性。该分离物在表型上对奥沙西林敏感,并且通过Southern印迹杂交不包含mecA基因。 oxacillin琼脂筛选试验,VITEK-1系统,VITEK-2系统和琼脂稀释液分别显示出99.0、99.0、99.5和99%的灵敏度,特异性分别为98.1、100、97.2和100% 。敏感性或特异性差异无统计学意义。奥沙西林杀菌试验表明,通过常规方法对抗葡萄球菌β-内酰胺敏感的mecA和PBP 2a阳性金黄色葡萄球菌分离物在功能上对奥沙西林具有抗性。我们得出的结论是,用于检测PBP 2a的MRSA-Screen乳胶凝集方法的准确性接近PCR的准确性,并且比单独用于检测MRSA的任何药敏试验方法更准确。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号