Comparison of the Binax Legionella Urinary Antigen Enzyme Immunoassay (EIA) with the Biotest Legionella Urin Antigen EIA for Detection of Legionella Antigen in both Concentrated and Nonconcentrated Urine Samples

机译:Binax军团菌尿液抗原酶联免疫测定(EIA)与Biotest军团菌尿液抗原EIA的比较可用于检测浓缩和非浓缩尿液样品中的军团菌抗原

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

We evaluated a newly commercial enzyme immunoassay (EIA) (Biotest Legionella Urin Antigen EIA; Biotest AG, Dreieich, Germany) for detection of antigens of all Legionella pneumophila serogroups with a relatively wide spectrum of cross-reactivity as well as antigens of other Legionella spp. by comparing its sensitivity and specificity with those of an EIA for detection of L. pneumophila serogroup 1 antigen (Legionella urinary antigen EIA; Binax, Portland, Maine). Both tests were performed with both concentrated and nonconcentrated urine samples. We also evaluated the capabilities of both EIAs to detect extracted soluble antigens of American Type Culture Collection (ATCC) Legionella strains (L. pneumophila serogroups 1 to 14, L. bozemanii, and L. longbeachae). The sensitivity of the Biotest EIA was 66.66% in nonconcentrated urine and 86.66% in concentrated urine. The sensitivity of the Binax EIA was 63.76% and 88.88% in nonconcentrated and concentrated urine, respectively. The specificity was 100% in nonconcentrated and concentrated urine for both assays. The Binax EIA and Biotest EIA detected extracted soluble antigens of L. pneumophila serogroups 1 to 14 and L. bozemanii ATCC strains. The cross-reactions observed with the Binax EIA were probably due to common epitopes directly related to lipopolysaccharide. Further studies are required to determine the usefulness of the Binax EIA for detection of urinary antigens from Legionella species and serogroups other than L. pneumophila serogroup 1. The Biotest EIA proved to be as rapid, sensitive, and specific as the Binax EIA for the diagnosis of legionellosis. Concentration of antigen present in urine increased the sensitivities of both techniques with no reduction in specificity.
机译:我们评估了一种新的商业酶免疫测定(EIA)(Biotest军团菌尿素抗原EIA; Biotest AG,Dreieich,德国),用于检测具有相对广谱交叉反应性的所有军团菌嗜肺菌血清群的抗原以及其他军团菌属菌种的抗原。通过将其敏感性和特异性与EIA检测肺炎嗜血杆菌血清群1抗原(Legionella尿液抗原EIA; Binax,缅因州波特纳)的灵敏度和特异性进行比较。两种测试均针对浓缩尿液样本和非浓缩尿液样本进行。我们还评估了两种EIA检测美国典型培养物保藏中心(ATCC)军团菌菌株(嗜肺乳杆菌血清群1至14,博兹曼乳杆菌和长滩乳杆菌)提取的可溶性抗原的能力。 Biotest EIA的灵敏度在非浓缩尿液中为66.66%,在浓缩尿液中为86.66%。 Binax EIA在非浓缩尿液和浓缩尿液中的敏感性分别为63.76%和88.88%。对于两种测定,在非浓缩和浓缩尿液中的特异性均为100%。 Binax EIA和Biotest EIA检测到了嗜肺乳杆菌血清群1至14和博兹曼乳杆菌ATCC菌株的提取可溶性抗原。 Binax EIA观察到的交叉反应可能是由于与脂多糖直接相关的常见表位所致。需要进一步的研究来确定Binax EIA对检测军团菌属和嗜肺乳杆菌血清群1以外的血清群中尿抗原的有用性。BiotestEIA被证明与Binax EIA一样快速,灵敏和特异,可用于诊断军团病。尿液中存在的抗原浓度增加了这两种技术的敏感性,但特异性并未降低。