首页> 美国卫生研究院文献>other >Concentration Gradient Immunoassay I. A Rapid Immunoassay Based on Interdiffusion and Surface Binding in a Microchannel
【2h】

Concentration Gradient Immunoassay I. A Rapid Immunoassay Based on Interdiffusion and Surface Binding in a Microchannel

机译:浓度梯度免疫分析I.基于互扩散和微通道表面结合的快速免疫分析

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

We describe a novel microfluidic immunoassay method based on the diffusion of a small molecule analyte into a parallel-flowing stream containing cognate antibody. This interdiffusion results in a steady-state gradient of antibody binding site occupancy transverse to convective flow. In contrast to the diffusion immunoassay (Hatch et al. Nature Biotechnology,19:461−465 (2001)), this antibody occupancy gradient is interrogated by a sensor surface coated with a functional analog of the analyte. Antibodies with at least one unoccupied binding site may specifically bind to this functionalized surface, leading to a quantifiable change in surface coverage by the antibody. SPR imaging is used to probe the spatial distribution of antibody binding to the surface and, therefore, the outcome of the assay. We show that the pattern of antibody binding to the SPR sensing surface correlates with the concentration of a model analyte (phenytoin) in the sample stream. Using an inexpensive disposable microfluidic device, we demonstrate assays for phenytoin ranging in concentration from 75 to 1000 nM in phosphate buffer. At a total volumetric flow rate of 90 nL/sec, the assays are complete within 10 minutes. Inclusion of an additional flow stream on the side of the antibody stream opposite to that of the sample enables simultaneous calibration of the assay. This assay method is suitable for rapid quantitative detection of low-molecular weight analytes for point-of-care diagnostic instrumentation.
机译:我们描述了一种基于小分子分析物扩散到包含同源抗体的平行流动物流中的新型微流免疫分析方法。这种相互扩散导致横向于对流流动的抗体结合位点占据的稳态梯度。与扩散免疫测定法(Hatch等人,Nature Biotechnology,19:461-465(2001))相反,该抗体的占据梯度被涂有分析物功能类似物的传感器表面询问。具有至少一个未占据的结合位点的抗体可以特异性结合该功能化的表面,从而导致抗体表面覆盖率的可量化变化。 SPR成像用于探测与表面结合的抗体的空间分布,从而探测测定的结果。我们显示抗体结合到SPR感应表面的模式与样品流中模型分析物(苯妥英)的浓度相关。使用廉价的一次性微流控设备,我们证明了苯妥英钠在磷酸盐缓冲液中的浓度范围为75至1000 nM。在总体积流量为90 nL / sec的情况下,分析将在10分钟内完成。在抗体流的与样品相反的一侧上包括另外的流流使得能够同时校准测定。这种测定方法适用于快速定量检测低分子量分析物,以用于即时诊断设备。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号