首页> 美国卫生研究院文献>other >Certification of Total Arsenic in Blood and Urine Standard Reference Materials by Radiochemical Neutron Activation Analysis and Inductively Coupled Plasma - Mass Spectrometry
【2h】

Certification of Total Arsenic in Blood and Urine Standard Reference Materials by Radiochemical Neutron Activation Analysis and Inductively Coupled Plasma - Mass Spectrometry

机译:放射化学中子活化分析和电感耦合等离子体质谱法测定血液和尿液标准参考物质中的总砷

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

A newly developed procedure for determination of arsenic by radiochemical neutron activation analysis (RNAA) was used to measure arsenic at four levels in SRM 955c Toxic Elements in Caprine Blood and at two levels in SRM 2668 Toxic Elements in Frozen Human Urine for the purpose of providing mass concentration values for certification. Samples were freeze-dried prior to analysis followed by neutron irradiation for 3 h at a fluence rate of 1×1014cm−2s−1. After sample dissolution in perchloric and nitric acids, arsenic was separated from the matrix by extraction into zinc diethyldithiocarbamate in chloroform, and 76As quantified by gamma-ray spectroscopy. Differences in chemical yield and counting geometry between samples and standards were monitored by measuring the count rate of a 77As tracer added before sample dissolution. RNAA results were combined with inductively coupled plasma – mass spectrometry (ICP-MS) values from NIST and collaborating laboratories to provide certified values of (10.81 ± 0.54) μg/kg and (213.1 ± 0.73) μg/kg for SRM 2668 Levels I and II, and certified values of (21.66 ± 0.73) μg/kg, (52.7 ± 1.1) μg/kg, and (78.8 ± 4.9) μg/kg for SRM 955c Levels 2, 3, and 4 respectively. Because of discrepancies between values obtained by different methods for SRM 955c Level 1, an information value of < 5 μg/kg was assigned for this material.
机译:为了提供一种通过放射化学中子活化分析(RNAA)测定砷的新方法,该方法可以测量SRM 955c鸡血中有毒元素的四个水平和SRM 2668冷冻人尿液中有毒元素的两个水平的砷。质量浓度值进行认证。将样品冷冻干燥,然后进行分析,然后以1×10 14 cm -2 s -1 。将样品溶解在高氯酸和硝酸中后,通过萃取到氯仿中的二乙基二硫代氨基甲酸锌中,并通过γ射线光谱法定量 76 ,从基质中分离出砷。通过测量样品溶解前添加的 77 As示踪剂的计数率,来监控样品与标准品之间化学产率和计数几何形状的差异。将RNAA结果与NIST和合作实验室的电感耦合等离子体质谱(ICP-MS)值相结合,得出SRM 2668 I级和SRM级的认证值分别为(10.81±0.54)μg/ kg和(213.1±0.73)μg/ kg。 II和SRM 955c第2、3和4级的认证值分别为(21.66±0.73)μg/ kg,(52.7±1.1)μg/ kg和(78.8±4.9)μg/ kg。由于通过SRM 955c Level 1的不同方法获得的值之间存在差异,因此为此材料指定了<5μg/ kg的信息值。

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号