Use of Recirculating Ventilation with Dust Filtration to Improve Wintertime Air Quality in a Swine Farrowing Room

机译:在猪场中使用循环通风和粉尘过滤来改善冬季空气质量

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The performance of a recirculating ventilation system with dust filtration was evaluated to determine its effectiveness to improve the air quality in a swine farrowing room of a concentrated animal feeding operation (CAFO). Air was exhausted from the room (0.47 m3sec−1; 1000 cfm), treated with a filtration unit (Shaker-Dust Collector), and returned to the farrowing room to reduce dust concentrations while retaining heat necessary for livestock health. The air quality in the room was assessed over a winter, during which time limited fresh air is traditionally brought into the building. Over the study period, dust concentrations ranged from 0.005 to 0.31 mg m−3 (respirable) and 0.17 to 2.09 mg m−3 (inhalable). In-room dust concentrations were reduced (41% for respirable and 33% for inhalable) with the system in operation, while gas concentrations (ammonia [NH3], hydrogen sulfide [H2S], carbon monoxide [CO], carbon dioxide [CO2]) were unchanged. The position of the exhaust and return air systems provided reasonably uniform contaminant distributions, although the respirable dust concentrations nearest one of the exhaust ducts was statistically higher than other locations in the room, with differences averaging only 0.05 mg m−3. Throughout the study, CO2 concentrations consistently exceeded 1540 ppm (industry recommendations) and on eight of the 18 study days it exceeded 2500 ppm (50% of the ACGIH TLV), with significantly higher concentrations near a door to a temperature-controlled hallway that was typically often left open. Alternative heaters are recommended to reduce CO2 concentrations in the room. Contaminant concentrations were modeled using production and environmental factors, with NH3 related to the number of sow in the room and outdoor temperatures and CO2 related to the number of piglets and outdoor temperatures. The recirculating ventilation system provided dust reduction without increasing concentrations of hazardous gases.
机译:评估了带灰尘过滤的循环通风系统的性能,以确定其在集中式动物饲养操作(CAFO)的猪产房中改善空气质量的有效性。空气从房间排出(0.47 m 3 sec -1 ; 1000 cfm),用过滤装置(Shaker-Dust Collector)进行处理,然后返回到产房在保持家畜健康所必需的热量的同时降低粉尘浓度。在整个冬季对房间的空气质量进行评估,在此期间,传统上将有限的新鲜空气引入建筑物。在研究期间,粉尘浓度范围为0.005至0.31 mg m -3 (可吸入)和0.17至2.09 mg m -3 (可吸入)。在系统运行时,室内灰尘浓度降低了(可吸入性降低了41%,可吸入性降低了33%),而气体浓度(氨气[NH3],硫化氢[H2S],一氧化碳[CO],二氧化碳[CO2] )保持不变。排气和回风系统的位置提供了合理均匀的污染物分布,尽管最接近排气管之一的可吸入粉尘浓度在统计上高于房间中的其他位置,平均差异仅为0.05 mg m −3 。在整个研究过程中,CO2浓度始终超过1540 ppm(行业建议),并且在18个研究日中有8天超过2500 ppm(ACGIH TLV的50%),靠近温度受控走廊的门附近的浓度明显更高。通常经常开着。建议使用备用加热器降低房间中的CO2浓度。利用生产和环境因素对污染物浓度进行建模,其中NH3与室内和室外温度的母猪数量有关,而CO2与仔猪的数量和室外温度有关。循环通风系统可减少粉尘,而不会增加有害气体的浓度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号