Up-flow column percolation tests are used at laboratory scale to assess the leaching behavior of hazardous substance from contaminated soils in a specific condition as a function of time. Monitoring the quality of these test results inter or within laboratory is crucial, especially if used for Environment-related legal policy or for routine testing purposes. We tested three different sandy loam type soils (Soils I, II and III) to determine the reproducibility (variability inter laboratory) of test results and to evaluate the difference in the test results within laboratory. Up-flow column percolation tests were performed following the procedure described in the ISO/TS 21268–3. This procedure consists of percolating solution (calcium chloride 1 mM) from bottom to top at a flow rate of 12 mL/h through softly compacted soil contained in a column of 5 cm diameter and 30 ± 5 cm height. Eluate samples were collected at liquid-to-solid ratio of 0.1, 0.2, 0.5, 1, 2, 5 and 10 L/kg and analyzed for quantification of the target elements (Cu, As, Se, Cl, Ca, F, Mg, DOC and B in this research). For Soil I, 17 institutions in Japan joined this validation test. The up-flow column experiments were conducted in duplicate, after 48 h of equilibration time and at a flow rate of 12 mL/h. Column percolation test results from Soils II and III were used to evaluate the difference in test results from the experiments conducted in duplicate in a single laboratory, after 16 h of equilibration time and at a flow rate of 36 mL/h. Overall results showed good reproducibility (expressed in terms of the coefficient of variation, CV, calculated by dividing the standard deviation by the mean), as the CV was lower than 30% in more than 90% of the test results associated with Soil I. Moreover, low variability (expressed in terms of difference between the two test results divided by the mean) was observed in the test results related to Soils II and III, with a variability lower than 30% in more than 88% of the cases for Soil II and in more than 96% of the cases for Soil III. We also discussed the possible factors that affect the reproducibility and variability in the test results from the up-flow column percolation tests. The low variability inter and within laboratory obtained in this research indicates that the ISO/TS 21268–3 can be successfully upgraded to a fully validated ISO standard.
机译:上流柱渗透试验用于实验室规模,以评估特定条件下受污染土壤中有害物质的浸出行为随时间的变化。在实验室内部或实验室内部监视这些测试结果的质量至关重要,尤其是在用于与环境有关的法律政策或用于常规测试目的的情况下。我们测试了三种不同的沙壤土类型土壤(土壤I,II和III),以确定测试结果的可重复性(实验室间的变异性)并评估实验室内测试结果的差异。按照ISO / TS 21268-3中所述的程序进行上流柱渗滤测试。此过程包括从底部到顶部以12 mL / h的流速通过直径5 cm,高度30±5 cm的软压实土壤渗滤溶液(氯化钙1 mM)。收集的洗提液样品的液固比为0.1、0.2、0.5、1、2、5和10 L / kg,并分析目标元素(Cu,As,Se,Cl,Ca,F,Mg ,DOC和B)。对于土壤I,日本的17个机构参加了此验证测试。在平衡时间48小时后,以12 mL / h的流速重复进行上流柱实验。在平衡时间16小时后,以36 mL / h的流速,使用来自土壤II和III的色谱柱渗透测试结果评估了在一个实验室中一式两份进行的实验的测试结果差异。总体结果显示出良好的可重复性(用变异系数CV表示,用标准偏差除以平均值计算得出),因为90%以上与土壤I相关的测试结果中CV均低于30%。此外,在与土壤II和土壤III相关的测试结果中观察到低变异性(用两个测试结果之差除以平均值表示),在超过88%的土壤案例中变异性低于30% II,在超过96%的土壤III中。我们还讨论了可能影响上游色谱柱渗滤测试结果的可重复性和可变性的因素。这项研究获得的实验室内部和内部的低变异性表明,ISO / TS 21268-3可成功升级到完全验证的ISO标准。

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号