Single tooth implant retained crowns have become a recognized technique for the replacement of the missing teeth. With the predictable integration of implants, the emphasis is shifted towards precise prosthesis. Minor movement of the impression coping retained inside the impression material can occur during all the procedures, leading to the three-dimensional spatial inaccuracies in the master casts. Therefore, the present study was undertaken with the purpose to evaluate the accuracy of single-tooth implant impression techniques using four different impression copings, so as to obtain a precise definitive cast for a single-unit implant restoration. A maxillary acrylic resin model with a standard single implant in the first molar region was used to simulate a clinical situation. A total of 60 impressions were made with polyvinylsiloxane impression material, which were divided into four groups of 15 impressions each. Group I used non-modified square impression coping, while in group II, III and IV square impression coping were modified differently. Master casts fabricated for all the groups were analyzed to detect rotational position change of the hexagon on the implant replicas in the master casts in reference to the resin model. The master casts obtained with the roughened and adhesive-coated impression copings showed a lower amount of rotational movement than the masters casts achieved with the non-modified impression copings. Hence, the clinician should use sandblasted and adhesive coated impression copings to achieve a more accurate and precise orientation of the implant replicas in the laboratory master casts in single-tooth implant restorations.
机译:单牙植入物保留的牙冠已成为公认的替代缺失牙的技术。随着植入物的可预测整合,重点已转向精确的假体。在所有过程中,压印材料内部保留的压印帽盖可能会发生轻微移动,从而导致母模中的三维空间不准确。因此,进行本研究的目的是评估使用四个不同的压印顶盖的单齿植入物压印技术的准确性,从而获得用于单个单元植入物修复的精确确定铸件。使用在第一磨牙区域中具有标准单个植入物的上颌丙烯酸树脂模型来模拟临床情况。用聚乙烯基硅氧烷印模材料制成总共60个印模,将其分为四组,每组15个印模。第一组使用未修改的方形印象应对,而第二,第三和第四组使用不同的方形印象应对。参考树脂模型,分析为所有组制造的母模,以检测母模中植入物复制品上六边形的旋转位置变化。与未改性的压印模版获得的母模相比,采用粗糙和粘合剂涂覆的压印模版获得的母模显示出更低的旋转运动量。因此,临床医生应使用喷砂和粘合剂涂层的压印帽,以在单齿植入物修复体的实验室主铸模中实现植入物复制品的更准确和精确的定向。

著录项

相似文献

  • 外文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号